| Assessment Year | 1986 |
|---|---|
| Principal Product | METAL HAND RAILINGS |
| NAICS |
n/a
|
| SIC | 3446: Architectural and Ornamental Metal Work |
| Sales Range | $5 M to 10M |
| # of Employees | 110 |
| Plant Area |
n/a
|
| Annual Production | 1,040,000
lb
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,793 | 491,794 |
kWh
|
$0.083 |
| Natural Gas | $26,525 | 6,921 |
MMBtu
|
$3.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,205 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,663 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $2,771 | $5,500 |
$2,771
33,411
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,677 | $1,581 |
$1,677
20,223
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,483 | $120 |
$1,483
17,878
kWh
|
- | - | |
| 04 | 2.4312: Improve lubrication practices | $1,460 | $2,135 |
$1,460
17,585
kWh
|
- | - | |
| 05 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $1,243 | $90 |
$186
2,345
kWh
|
$1,057
-
MMBtu
|
- | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $1,118 | $2,100 | - |
$1,118
-
MMBtu
|
- | |
| 07 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $740 | $10 |
$144
1,758
kWh
|
$596
-
MMBtu
|
- | |
| 08 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $173 | $1,500 |
$216
2,638
kWh
|
$(-43.0)
-
MMBtu
|
- | |
| 09 | 2.6214: Shut off pilots in standby equipment | $590 | - | - |
$540
-
MMBtu
|
$50 | |
| 10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $480 | $50 |
$480
5,862
kWh
|
- | - | |
| 11 | 2.7221: Lower temperature during the winter season and vice-versa | $155 | - |
$155
1,758
kWh
|
- | - | |
| 12 | 2.4221: Install compressor air intakes in coolest locations | $177 | $200 |
$177
2,052
kWh
|
- | - | |
| 13 | 2.6121: Reduce hot water temperature to the minimum required | $138 | - |
$138
1,758
kWh
|
- | - | |
| TOTAL RECOMMENDED | $12,205 | $13,286 |
$8,887
107,268
kWh
|
$3,268
-
MMBtu
|
$50 | ||
| TOTAL IMPLEMENTED | $7,663 | $4,136 |
$5,420
65,357
kWh
|
$2,193
-
MMBtu
|
$50 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs