Assessment Year 1986
Principal Product PRINTED PAPER
NAICS
n/a
SIC 2752: Commercial Printing, Lithographic
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area
n/a
Annual Production 11,000
ton
Production Hrs. Annual 6,240
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $354,631 6,458,968
kWh
Natural Gas $108,700 26,456
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $137,726 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,489

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $109,167 $1,000,000 $331,148
6,031,946
kWh
$(-221,981.0)
-
MMBtu
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $14,883 $10,000 $14,883
271,102
kWh
- -
03 2.4231: Reduce the pressure of compressed air to the minimum required $2,269 $20 $2,269
41,325
kWh
- -
04 2.4221: Install compressor air intakes in coolest locations $418 $700 $418
7,620
kWh
- -
05 2.1123: Install automatic stack damper $3,144 $3,000 - $3,144
-
MMBtu
-
06 2.1233: Analyze flue gas for proper air/fuel ratio $882 $2,000 - $1,032
-
MMBtu
$(-150.0)
07 2.2422: Use waste heat from hot flue gases to generate steam $801 $1,400 - $801
-
MMBtu
-
08 2.6121: Reduce hot water temperature to the minimum required $160 - - $160
-
MMBtu
-
09 2.4312: Improve lubrication practices $6,002 $4,500 $6,002
109,320
kWh
- -
TOTAL RECOMMENDED $137,726 $1,021,620 $354,720
6,461,313
kWh
$(-216,844.0)
-
MMBtu
$(-150.0)
TOTAL IMPLEMENTED $25,489 $20,200 $21,303
388,042
kWh
$4,336
-
MMBtu
$(-150.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs