| Assessment Year | 1981 |
|---|---|
| Principal Product | INDUSTRIAL & RETAIL CLEANING |
| NAICS |
n/a
|
| SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 120 |
| Plant Area |
n/a
|
| Annual Production | 7,800,000
lb
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $36,323 | 703,986 |
kWh
|
$0.052 |
| Natural Gas | $79,820 | 29,097 |
MMBtu
|
$2.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,353 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,023 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $497 | $1,471 |
$497
9,672
kWh
|
- | |
| 02 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $748 | $928 | - |
$748
-
MMBtu
|
|
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $15,275 | $39,000 | - |
$15,275
-
MMBtu
|
|
| 04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $2,861 | $1,500 | - |
$2,861
-
MMBtu
|
|
| 05 | 2.4221: Install compressor air intakes in coolest locations | $180 | $450 |
$180
3,517
kWh
|
- | |
| 06 | 2.2511: Insulate bare equipment | $792 | $700 | - |
$792
-
MMBtu
|
|
| TOTAL RECOMMENDED | $20,353 | $44,049 |
$677
13,189
kWh
|
$19,676
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $16,023 | $39,928 | - |
$16,023
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs