Assessment Year | 1981 |
---|---|
Principal Product | INDUSTRIAL & RETAIL CLEANING |
NAICS |
n/a
|
SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 7,800,000
lb
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $36,323 | 703,986 |
kWh
|
$0.052 |
Natural Gas | $79,820 | 29,097 |
MMBtu
|
$2.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,353 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,023 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $497 | $1,471 |
$497
9,672
kWh
|
- | |
02 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $748 | $928 | - |
$748
-
MMBtu
|
|
03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $15,275 | $39,000 | - |
$15,275
-
MMBtu
|
|
04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $2,861 | $1,500 | - |
$2,861
-
MMBtu
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $180 | $450 |
$180
3,517
kWh
|
- | |
06 | 2.2511: Insulate bare equipment | $792 | $700 | - |
$792
-
MMBtu
|
|
TOTAL RECOMMENDED | $20,353 | $44,049 |
$677
13,189
kWh
|
$19,676
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,023 | $39,928 | - |
$16,023
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs