ITAC Assessment: KS2207
ITAC logo
ITAC Assessment: KS2207
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2022
Principal Product Aluminum Knuckles
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 393
Plant Area 130,000
ft2
Annual Production 2,100,000
units
Production Hrs. Annual 6,240
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,036,757 20,618,215
kWh
Electricity Demand $247,611 47,236
kW-mo/yr
Electricity Fees $38,424 -
Natural Gas $240,911 53,154
MMBtu
Waste Disposal Costs
Water Usage $12,693 3,154
Tgal
Water Disposal $27,960 3,154
Tgal
TOTAL YEARLY COSTS $1,604,356
RECOMMENDED SAVINGS* $638,178 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $38,106

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
01 2.8121: Apply for tax-free status for energy purchases $28,812 $1,600 - - $11,153 $17,659
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,721 $18,007 $3,460
68,787
kWh
$747
-
kW-mo/yr
$514 -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,500 $5,480 $6,249
124,243
kWh
$1,251
-
kW-mo/yr
- -
04 2.6127: Maintain air filters by cleaning or replacement $2,371 $2,138 $1,975
39,260
kWh
$396
-
kW-mo/yr
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,662 $2,460 $2,217
44,070
kWh
$445
-
kW-mo/yr
- -
06 2.7442: Keep doors and windows shut when not on use $2,202 - $1,835
36,480
kWh
$367
-
kW-mo/yr
- -
07 2.9114: Use solar heat to make electricty $589,910 $5,416,800 $547,262
10,879,955
kWh
$42,648
-
kW-mo/yr
- -
TOTAL RECOMMENDED $638,178 $5,446,485 $562,998
11,192,795
kWh
$45,854
-
kW-mo/yr
$11,667 $17,659
TOTAL IMPLEMENTED $38,106 $21,745 $7,270
144,527
kWh
$1,510
-
kW-mo/yr
$11,667 $17,659
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Administrative Changes Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs