Assessment Year | 1997 |
---|---|
Principal Product | parts for electric motor |
NAICS |
n/a
|
SIC | 3621: Motors and Generators |
Sales Range | $5 M to 10M |
# of Employees | 96 |
Plant Area |
22,704
ft2
|
Annual Production | 10,500,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $150,454 | 3,026,671 |
kWh
|
$0.050 |
Electricity Demand | $15,640 | 6,730 |
kW-mo/yr
|
$2.32 |
Electricity Fees | $4,877 | - |
|
- |
Natural Gas | $62,267 | 12,377 |
MMBtu
|
$5.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,053 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,181 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,975 | $13,250 |
$11,864
239,156
kWh
|
$1,111
-
kW-mo/yr
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $10,914 | $14,980 |
$10,154
204,572
kWh
|
$760
-
kW-mo/yr
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,365 | $1,750 |
$2,163
43,669
kWh
|
$202
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,051 | $394 |
$937
18,757
kWh
|
$114
-
kW-mo/yr
|
- | |
05 | 2.7261: Install timers and/or thermostats | $960 | $300 |
$960
19,343
kWh
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $924 | $25 |
$845
16,999
kWh
|
$79
-
kW-mo/yr
|
- | |
07 | 2.7135: Install occupancy sensors | $608 | $130 |
$608
14,361
kWh
|
- | - | |
08 | 3.4151: Minimize water usage | $2,256 | $2,850 | - | - |
$2,256
-
Tgal
|
|
TOTAL RECOMMENDED | $32,053 | $33,679 |
$27,531
556,857
kWh
|
$2,266
-
kW-mo/yr
|
$2,256
-
Tgal
|
||
TOTAL IMPLEMENTED | $15,181 | $18,524 |
$12,051
242,672
kWh
|
$874
-
kW-mo/yr
|
$2,256
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs