| Assessment Year | 1996 |
|---|---|
| Principal Product | Concrete pipe and Pre-cast |
| NAICS |
n/a
|
| SIC | 3273: Ready-Mixed Concrete |
| Sales Range | $50 M to 100M |
| # of Employees | 40 |
| Plant Area |
1,020,085
ft2
|
| Annual Production | 66,000
ton
|
| Production Hrs. Annual | 3,125
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $161,544 | 1,572,098 |
kWh
|
$0.10 |
| Electricity Demand | $54,944 | 8,655 |
kW-mo/yr
|
$6.35 |
| Electricity Fees | $6,869 | - |
|
- |
| Natural Gas | $35,225 | 6,767 |
MMBtu
|
$5.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $36,333 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $33,916 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,417 | - | - | - | $2,417 | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $2,060 | $4,750 |
$1,629
26,084
kWh
|
$431
-
kW-mo/yr
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,084 | $464 |
$726
11,723
kWh
|
$358
-
kW-mo/yr
|
- | - | |
| 04 | 2.7261: Install timers and/or thermostats | $2,582 | $600 |
$2,582
41,325
kWh
|
- | - | - | |
| 05 | 3.1192: Reduce scrap production | $3,326 | $500 | - | - | - |
$3,326
-
lb
|
|
| 06 | 3.1192: Reduce scrap production | $24,864 | $5,000 | - | - | - |
$24,864
-
lb
|
|
| TOTAL RECOMMENDED | $36,333 | $11,314 |
$4,937
79,132
kWh
|
$789
-
kW-mo/yr
|
$2,417 |
$28,190
-
lb
|
||
| TOTAL IMPLEMENTED | $33,916 | $11,314 |
$4,937
79,132
kWh
|
$789
-
kW-mo/yr
|
- |
$28,190
-
lb
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs