Assessment Year | 1996 |
---|---|
Principal Product | Sausage for private labels. |
NAICS |
n/a
|
SIC | 2011: Meat Packing Plants |
Sales Range | $10 M to 50M |
# of Employees | 175 |
Plant Area |
76,000
ft2
|
Annual Production | 25,000,000
lb
|
Production Hrs. Annual | 3,432
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $303,884 | 5,081,184 |
kWh
|
$0.060 |
Electricity Demand | $85,886 | 12,630 |
kW-mo/yr
|
$6.80 |
Natural Gas | $60,116 | 23,905 |
MMBtu
|
$2.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $227,901 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,704 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $201,031 | $1,200,000 |
$157,872
3,432,298
kWh
|
$81,600
-
kW-mo/yr
|
$(-38,441.0)
-
MMBtu
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $4,732 | $9,920 |
$3,501
76,202
kWh
|
$1,231
-
kW-mo/yr
|
- | - | - | |
03 | 2.7261: Install timers and/or thermostats | $1,761 | $600 |
$1,761
38,394
kWh
|
- | - | - | - | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $1,166 | $2,275 | - | - |
$1,166
-
MMBtu
|
- | - | |
05 | 2.7229: Air condition only space necessary | $987 | - |
$343
7,327
kWh
|
$70
-
kW-mo/yr
|
$574
-
MMBtu
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,396 | $482 |
$1,102
24,033
kWh
|
$294
-
kW-mo/yr
|
- | - | - | |
07 | 3.4151: Minimize water usage | $12,749 | $1,904 | - | - | - |
$12,749
-
Tgal
|
- | |
08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,723 | $425 | - | - | - | - |
$1,723
-
lb
|
|
09 | 3.5311: Recover and reuse waste material | $2,356 | $500 | - | - | - | - |
$2,356
-
lb
|
|
TOTAL RECOMMENDED | $227,901 | $1,216,106 |
$164,579
3,578,254
kWh
|
$83,195
-
kW-mo/yr
|
$(-36,701.0)
-
MMBtu
|
$12,749
-
Tgal
|
$4,079
-
lb
|
||
TOTAL IMPLEMENTED | $25,704 | $13,831 |
$6,707
145,956
kWh
|
$1,595
-
kW-mo/yr
|
$574
-
MMBtu
|
$12,749
-
Tgal
|
$4,079
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs