Assessment Year | 2004 |
---|---|
Principal Product | Clay Tiles |
NAICS | 327120: Clay Building Material and Refractories Manufacturing |
SIC | 3253: Ceramic Wall and Floor Tile |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
65,750
ft2
|
Annual Production | 11,500,000
pieces
|
Production Hrs. Annual | 6,528
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $100,465 | 789,333 |
kWh
|
$0.13 |
Electricity Demand | $8,193 | 2,077 |
kW-mo/yr
|
$3.94 |
Natural Gas | $208,785 | 27,234 |
MMBtu
|
$7.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,806 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,116 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $850 | $282 |
$806
6,340
kWh
|
$44
-
kW-mo/yr
|
- | - | - | |
02 | 2.8114: Change rate schedules or other changes in utility service | $8,781 | $4,375 | - | - | $8,781 | - | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,936 | $3,085 |
$4,672
36,663
kWh
|
$264
-
kW-mo/yr
|
- | - | - | |
04 | 2.7134: Use photocell controls | $2,262 | $2,760 |
$1,951
15,339
kWh
|
$311
-
kW-mo/yr
|
- | - | - | |
05 | 2.7134: Use photocell controls | $2,058 | $2,880 |
$1,746
13,728
kWh
|
$312
-
kW-mo/yr
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,715 | $2,638 |
$1,620
12,733
kWh
|
$95
-
kW-mo/yr
|
- | - | - | |
07 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $753 | $1,520 | - | - | - |
$753
-
MMBtu
|
- | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,293 | $5,681 |
$2,293
18,032
kWh
|
- | - | - | - | |
09 | 2.7134: Use photocell controls | $1,017 | $3,059 |
$900
7,077
kWh
|
$117
-
kW-mo/yr
|
- | - | - | |
10 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $14,141 | $36,000 | - | - | - | - |
$14,141
-
lb
|
|
TOTAL RECOMMENDED | $38,806 | $62,280 |
$13,988
109,912
kWh
|
$1,143
-
kW-mo/yr
|
$8,781 |
$753
-
MMBtu
|
$14,141
-
lb
|
||
TOTAL IMPLEMENTED | $13,116 | $11,874 |
$3,326
26,150
kWh
|
$256
-
kW-mo/yr
|
$8,781 |
$753
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs