| Assessment Year | 1995 |
|---|---|
| Principal Product | Soft Drinking Bottling |
| NAICS |
n/a
|
| SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
| Sales Range | $10 M to 50M |
| # of Employees | 225 |
| Plant Area |
162,528
ft2
|
| Annual Production | 9,000,000
units
|
| Production Hrs. Annual | 2,600
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $355,614 | 4,912,954 |
kWh
|
$0.072 |
| Natural Gas | $47,671 | 12,864 |
MMBtu
|
$3.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,212 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $27,639 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $12,881 | $8,540 |
$12,881
142,732
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $8,508 | $35,590 |
$8,508
128,077
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,573 | - |
$3,573
39,566
kWh
|
- | |
| 04 | 2.4314: Use synthetic lubricant | $2,418 | $997 |
$2,418
26,671
kWh
|
- | |
| 05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,473 | $1,500 | - |
$1,473
-
MMBtu
|
|
| 06 | 2.7261: Install timers and/or thermostats | $1,314 | $1,650 |
$1,314
47,186
kWh
|
- | |
| 07 | 2.7261: Install timers and/or thermostats | $1,045 | $1,200 |
$1,045
37,515
kWh
|
- | |
| TOTAL RECOMMENDED | $31,212 | $49,477 |
$29,739
421,747
kWh
|
$1,473
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $27,639 | $49,477 |
$26,166
382,181
kWh
|
$1,473
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs