Assessment Year | 1995 |
---|---|
Principal Product | Soft Drinking Bottling |
NAICS |
n/a
|
SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
Sales Range | $10 M to 50M |
# of Employees | 225 |
Plant Area |
162,528
ft2
|
Annual Production | 9,000,000
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $355,614 | 4,912,954 |
kWh
|
$0.072 |
Natural Gas | $47,671 | 12,864 |
MMBtu
|
$3.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,212 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,639 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $12,881 | $8,540 |
$12,881
142,732
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $8,508 | $35,590 |
$8,508
128,077
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,573 | - |
$3,573
39,566
kWh
|
- | |
04 | 2.4314: Use synthetic lubricant | $2,418 | $997 |
$2,418
26,671
kWh
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,473 | $1,500 | - |
$1,473
-
MMBtu
|
|
06 | 2.7261: Install timers and/or thermostats | $1,314 | $1,650 |
$1,314
47,186
kWh
|
- | |
07 | 2.7261: Install timers and/or thermostats | $1,045 | $1,200 |
$1,045
37,515
kWh
|
- | |
TOTAL RECOMMENDED | $31,212 | $49,477 |
$29,739
421,747
kWh
|
$1,473
-
MMBtu
|
||
TOTAL IMPLEMENTED | $27,639 | $49,477 |
$26,166
382,181
kWh
|
$1,473
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs