| Assessment Year | 1995 |
|---|---|
| Principal Product | Injection molded plastic parts |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
32,500
ft2
|
| Annual Production | 750,000
lb
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $259,077 | 3,905,920 |
kWh
|
$0.066 |
| Natural Gas | $8,103 | 1,648 |
MMBtu
|
$4.92 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,238 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $3,702 | $3,130 | n/a |
$3,702
56,272
kWh
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,380 | $6,628 | n/a |
$3,380
51,290
kWh
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $992 | $50 | n/a |
$992
14,947
kWh
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $164 | $600 | n/a |
$164
2,638
kWh
|
| TOTAL RECOMMENDED | $8,238 | $10,408 |
$8,238
125,147
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs