Assessment Year | 1995 |
---|---|
Principal Product | Children's sleepwear |
NAICS |
n/a
|
SIC | 2341: Women's, Misses', Children's, and Infants' Underwear and Nightwear |
Sales Range | $10 M to 50M |
# of Employees | 520 |
Plant Area |
86,500
ft2
|
Annual Production | 623,000
pieces
|
Production Hrs. Annual | 2,468
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $221,045 | 2,563,306 |
kWh
|
$0.086 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $105,295 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2692: Use outside cold water source as a supply of cooling water | $84,629 | $240,000 |
$84,629
1,183,470
kWh
|
|
02 | 2.7241: Install outside air damper / economizer on hvac unit | $14,244 | $2,280 |
$14,244
432,884
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,352 | $1,521 |
$3,352
33,118
kWh
|
|
04 | 2.7261: Install timers and/or thermostats | $1,757 | $450 |
$1,757
53,341
kWh
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,190 | $20 |
$1,190
11,723
kWh
|
|
06 | 2.6218: Turn off equipment when not in use | $123 | $180 |
$123
3,810
kWh
|
|
TOTAL RECOMMENDED | $105,295 | $244,451 |
$105,295
1,718,346
kWh
|
||
TOTAL IMPLEMENTED | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs