| Assessment Year | 1995 |
|---|---|
| Principal Product | Milk processing and plastic bottles for milk and orange juic |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
38,877
ft2
|
| Annual Production | 16,000
Tgal
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $306,501 | 5,638,042 |
kWh
|
$0.054 |
| Natural Gas | $14,003 | 4,892 |
MMBtu
|
$2.86 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,839 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,341 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $6,677 | $15,450 |
$6,677
193,728
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,148 | $453 |
$2,148
40,152
kWh
|
- | |
| 03 | 2.2511: Insulate bare equipment | $1,300 | $107 |
$1,300
25,791
kWh
|
- | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,079 | $1,470 |
$1,079
37,808
kWh
|
- | |
| 05 | 2.7135: Install occupancy sensors | $795 | $260 |
$795
27,843
kWh
|
- | |
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $421 | $1,250 | - |
$421
-
MMBtu
|
|
| 07 | 2.7261: Install timers and/or thermostats | $419 | $300 |
$419
14,654
kWh
|
- | |
| TOTAL RECOMMENDED | $12,839 | $19,290 |
$12,418
339,976
kWh
|
$421
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,341 | $17,520 |
$10,920
287,514
kWh
|
$421
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs