| Assessment Year | 2026 |
|---|---|
| Principal Product | Metal fabrication |
| NAICS | 332322: Sheet Metal Work Manufacturing |
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 41 |
| Plant Area |
72,000
ft2
|
| Annual Production | 15,111,099
pieces
|
| Production Hrs. Annual | 4,208
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $97,609 | 1,095,000 |
kWh
|
$0.089 | |
| Natural Gas | $12,794 | 1,233 |
MMBtu
|
$10.38 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,435 | 205 |
Tgal
|
$6.99 | |
| Water Disposal | $2,310 | 205 |
Tgal
|
$11.25 | |
| TOTAL YEARLY COSTS | $114,148 | ||||
| RECOMMENDED SAVINGS* | $9,694 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $3,464 | $731 |
$3,464
38,924
kWh
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $4,828 | $3,830 |
$(-279.0)
(-3,138)
kWh
|
$5,107
-
MMBtu
|
|
| 03 | 2.4224: Upgrade controls on compressors | $953 | $1,752 |
$953
10,710
kWh
|
- | |
| 04 | 2.7135: Install occupancy sensors | $449 | $929 |
$449
5,049
kWh
|
- | |
| TOTAL RECOMMENDED | $9,694 | $7,242 |
$4,587
51,545
kWh
|
$5,107
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||