| Assessment Year | 2026 |
|---|---|
| Principal Product | Plastic Auto Parts |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 435 |
| Plant Area |
225,000
ft2
|
| Annual Production | 23,000,000
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $534,018 | 10,980,000 |
kWh
|
$0.049 | |
| Electricity Demand | $332,557 | 25,452 |
kW-mo/yr
|
$13.07 | |
| Electricity Fees | $3,300 | - |
|
- | |
| Natural Gas | $35,662 | 4,616 |
MMBtu
|
$7.73 | |
| Waste Disposal Costs | |||||
| Water Usage | $13,337 | 2,425 |
Tgal
|
$5.50 | |
| Water Disposal | $30,070 | 2,425 |
Tgal
|
$12.40 | |
| TOTAL YEARLY COSTS | $948,944 | ||||
| RECOMMENDED SAVINGS* | $244,589 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings | Water Usage Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2611: Moderate cooling tower outlet temperature | $73,439 | - |
$38,831
792,472
kWh
|
$31,073
-
kW-mo/yr
|
- | - |
$1,086
-
Tgal
|
$2,449
-
Tgal
|
|
| 02 | 2.3132: Recharge batteries on during off-peak demand periods | $9,724 | - | - |
$9,724
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $9,717 | - |
$9,717
198,305
kWh
|
- | - | - | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $5,372 | $1,319 | - | - |
$5,372
-
MMBtu
|
- | - | - | |
| 05 | 2.9114: Use solar heat to make electricty | $92,696 | $900,763 |
$63,918
1,304,451
kWh
|
$28,778
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $2,631 | $974 |
$1,742
35,568
kWh
|
$889
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.1321: Replace fossil fuel equipment with electrical equipment | $51,010 | $80,000 |
$(-7,338.0)
(-149,760)
kWh
|
- | - |
$58,348
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $244,589 | $983,056 |
$106,870
2,181,036
kWh
|
$70,464
-
kW-mo/yr
|
$5,372
-
MMBtu
|
$58,348
-
MMBtu
|
$1,086
-
Tgal
|
$2,449
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings | Water Usage Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs