Assessment Year | 2025 |
---|---|
Principal Product | Printed Food Packaging |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
266,900
ft2
|
Annual Production | 13,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $478,447 | 10,074,688 |
kWh
|
$0.047 | |
Electricity Demand | $401,762 | 24,617 |
kW-mo/yr
|
$16.32 | |
Electricity Fees | $1,898 | - |
|
- | |
Natural Gas | $196,058 | 57,272 |
MMBtu
|
$3.42 | |
Waste Disposal Costs | |||||
Water Usage | $34,877 | 6,575 |
Tgal
|
$5.30 | |
Water Disposal | $29,546 | 6,248 |
Tgal
|
$4.73 | |
TOTAL YEARLY COSTS | $1,142,588 | ||||
RECOMMENDED SAVINGS* | $43,701 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $11,808 | - |
$6,421
135,182
kWh
|
- |
$5,387
-
MMBtu
|
|
02 | 2.4224: Upgrade controls on compressors | $4,072 | - |
$2,055
43,260
kWh
|
$2,017
-
kW-mo/yr
|
- | |
03 | 2.2625: Chill water to the highest temperature possible | $910 | - |
$910
19,167
kWh
|
- | - | |
04 | 2.7241: Install outside air damper / economizer on hvac unit | $336 | - |
$336
7,080
kWh
|
- | - | |
05 | 2.7141: Lower light fixtures in high ceiling areas | $9,829 | $238 |
$6,593
138,802
kWh
|
$3,236
-
kW-mo/yr
|
- | |
06 | 2.1123: Install automatic stack damper | $9,546 | $1,395 |
$8,077
170,040
kWh
|
$1,469
-
kW-mo/yr
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,200 | $1,306 |
$4,687
98,673
kWh
|
$2,513
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $43,701 | $2,939 |
$29,079
612,204
kWh
|
$9,235
-
kW-mo/yr
|
$5,387
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs