| Assessment Year | 2025 |
|---|---|
| Principal Product | Recycling plastic |
| NAICS | 325991: Custom Compounding of Purchased Resins |
| SIC | 3087: Custom Compounding of Purchased Plastics Resins |
| Sales Range | $10 M to 50M |
| # of Employees | 116 |
| Plant Area |
205,000
ft2
|
| Annual Production | 104,058,737
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $653,682 | 7,542,812 |
kWh
|
$0.087 | |
| Electricity Demand | $195,140 | 19,879 |
kW-mo/yr
|
$9.82 | |
| Electricity Fees | $892 | - |
|
- | |
| LPG | $42,109 | 2,730 |
MMBtu
|
$15.42 | |
| Waste Disposal Costs | |||||
| Water Usage | $15,211 | 1,365 |
Tgal
|
$11.14 | |
| TOTAL YEARLY COSTS | $907,034 | ||||
| RECOMMENDED SAVINGS* | $194,269 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 3.1194: Use automatic flow control | $56,666 | $700 |
$21,903
251,756
kWh
|
$34,763
-
kW-mo/yr
|
|
| 02 | 2.1123: Install automatic stack damper | $55,966 | $1,300 |
$49,092
564,271
kWh
|
$6,874
-
kW-mo/yr
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,564 | $44 |
$4,564
52,465
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $10,015 | $1,072 |
$9,837
113,069
kWh
|
$178
-
kW-mo/yr
|
|
| 05 | 2.3191: Use demand controller or load shedder | $64,223 | $20,000 | - |
$64,223
-
kW-mo/yr
|
|
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,835 | $1,480 |
$2,329
26,773
kWh
|
$506
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $194,269 | $24,596 |
$87,725
1,008,334
kWh
|
$106,544
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs