| Assessment Year | 1989 |
|---|---|
| Principal Product | VINYL FLOOR TILES |
| NAICS |
n/a
|
| SIC | 3996: Linoleum, Asphalted-Felt-Base, and Other Hard Surface Floor Coverings, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 185 |
| Plant Area |
n/a
|
| Annual Production | 85,000
thousand feet
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Mississippi |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $995,619 | 18,516,120 |
kWh
|
$0.054 |
| Natural Gas | $236,838 | 83,717 |
MMBtu
|
$2.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $69,021 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,558 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $15,043 | $25,000 |
$(-1,437.0)
(-36,342)
kWh
|
$16,480
-
MMBtu
|
|
| 02 | 2.7231: Use radiant heater for spot heating | $46,420 | $3,100 | - |
$46,420
-
MMBtu
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $6,098 | $10,238 |
$6,098
147,421
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,460 | $417 |
$1,460
39,273
kWh
|
- | |
| TOTAL RECOMMENDED | $69,021 | $38,755 |
$6,121
150,352
kWh
|
$62,900
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $7,558 | $10,655 |
$7,558
186,694
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs