| Assessment Year | 2024 |
|---|---|
| Principal Product | Plastic Parts |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 51 |
| Plant Area |
68,062
ft2
|
| Annual Production | 9,746,454
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $170,110 | 1,479,558 |
kWh
|
$0.11 | |
| Electricity Demand | $43,900 | 4,466 |
kW-mo/yr
|
$9.83 | |
| Electricity Fees | $4,429 | - |
|
- | |
| Natural Gas | $6,133 | 675 |
MMBtu
|
$9.09 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,010 | 82 |
Tgal
|
$12.27 | |
| Water Disposal | $3,010 | 82 |
Tgal
|
$36.57 | |
| TOTAL YEARLY COSTS | $228,592 | ||||
| RECOMMENDED SAVINGS* | $7,902 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $7,339 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6211: Conserve energy by efficient use of vending machines | $507 | - |
$452
4,110
kWh
|
$55
-
kW-mo/yr
|
|
| 02 | 4.454: Modify startup/shutdown times | $1,880 | $40 | - |
$1,880
-
kW-mo/yr
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,126 | $42 |
$1,126
10,234
kWh
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $563 | $520 |
$480
4,368
kWh
|
$83
-
kW-mo/yr
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,327 | $2,497 |
$1,986
18,054
kWh
|
$341
-
kW-mo/yr
|
|
| 06 | 2.7135: Install occupancy sensors | $1,499 | $2,975 |
$1,499
13,627
kWh
|
- | |
| TOTAL RECOMMENDED | $7,902 | $6,074 |
$5,543
50,393
kWh
|
$2,359
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $7,339 | $5,554 |
$5,063
46,025
kWh
|
$2,276
-
kW-mo/yr
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs