Assessment Year | 2021 |
---|---|
Principal Product | Sound and Vibration Products |
NAICS | 336412: Aircraft Engine and Engine Parts Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 20 |
Plant Area |
58,987
ft2
|
Annual Production | 210,000
pieces
|
Production Hrs. Annual | 3,900
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $96,391 | 1,197,204 |
kWh
|
$0.081 | |
Electricity Demand | $20,706 | 3,857 |
kW-mo/yr
|
$5.37 | |
Electricity Fees | $58,561 | - |
|
- | |
Natural Gas | $15,334 | 2,418 |
MMBtu
|
$6.34 | |
Waste Disposal Costs | |||||
Water Usage | $2,351 | 193 |
Tgal
|
$12.18 | |
TOTAL YEARLY COSTS | $193,343 | ||||
RECOMMENDED SAVINGS* | $34,041 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $5,989 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $580 | - | - | - | $580 | - | |
02 | 2.8112: Combine utility meters | $494 | - | - | - | $494 | - | |
03 | 2.3212: Optimize plant power factor | $14,194 | $1,910 | - | - | $14,194 | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $94 | $40 |
$71
939
kWh
|
$23
-
kW-mo/yr
|
- | - | |
05 | 2.7135: Install occupancy sensors | $402 | $200 |
$402
5,313
kWh
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $146 | $100 |
$110
1,455
kWh
|
$36
-
kW-mo/yr
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $804 | $728 |
$640
8,502
kWh
|
$164
-
kW-mo/yr
|
- | - | |
08 | 2.8121: Apply for tax-free status for energy purchases | $6,803 | $8,000 | - | - | $6,803 | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $25 | $40 |
$17
234
kWh
|
$8
-
kW-mo/yr
|
- | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,597 | $14,185 |
$3,422
45,406
kWh
|
$1,175
-
kW-mo/yr
|
- | - | |
11 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $5,902 | $22,000 | - | - | - |
$5,902
-
MMBtu
|
|
TOTAL RECOMMENDED | $34,041 | $47,203 |
$4,662
61,849
kWh
|
$1,406
-
kW-mo/yr
|
$22,071 |
$5,902
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,989 | $14,953 |
$4,133
54,847
kWh
|
$1,362
-
kW-mo/yr
|
$494 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs