ITAC Assessment: IP0131
ITAC logo
ITAC Assessment: IP0131
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2020
Principal Product Architectural Millwork
NAICS 321918: Other Millwork (including Flooring)
SIC 2431: Millwork
Sales Range $50
M
to 100
M
# of Employees 330
Plant Area 800,000
ft2
Annual Production 2,100
thousand feet
Production Hrs. Annual 5,000
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $575,498 10,819,200
kWh
Electricity Demand $417,916 31,926
kW-mo/yr
Electricity Fees $2,400 -
Waste Disposal Costs
Water Disposal $10,567 1,540
Tgal
TOTAL YEARLY COSTS $1,006,381
RECOMMENDED SAVINGS* $57,122 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $38,471

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4322: Use or replace with energy efficient substitutes $3,141 - $2,349
44,150
kWh
$792
-
kW-mo/yr
02 2.4231: Reduce the pressure of compressed air to the minimum required $5,581 $300 $3,509
65,961
kWh
$2,072
-
kW-mo/yr
03 2.6212: Turn off equipment during breaks, reduce operating time $8,015 $2,880 $8,015
150,660
kWh
-
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $5,385 $2,100 $5,385
101,223
kWh
-
05 2.7135: Install occupancy sensors $1,682 $945 $1,682
31,624
kWh
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,356 $1,500 $1,482
27,850
kWh
$874
-
kW-mo/yr
07 2.4221: Install compressor air intakes in coolest locations $1,109 $1,524 $697
13,100
kWh
$412
-
kW-mo/yr
08 2.7142: Utilize higher efficiency lamps and/or ballasts $11,771 $31,062 $7,399
139,085
kWh
$4,372
-
kW-mo/yr
09 2.4133: Use most efficient type of electric motors $428 $1,430 $269
5,050
kWh
$159
-
kW-mo/yr
10 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $17,654 $60,600 $9,988
187,750
kWh
$7,666
-
kW-mo/yr
TOTAL RECOMMENDED $57,122 $102,341 $40,775
766,453
kWh
$16,347
-
kW-mo/yr
TOTAL IMPLEMENTED $38,471 $94,986 $23,075
433,746
kWh
$15,396
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs