Assessment Year | 2017 |
---|---|
Principal Product | Automotive Brake Hoses |
NAICS | 326220: Rubber and Plastics Hoses and Belting Manufacturing |
SIC | 3052: Rubber and Plastics Hose and Belting |
Sales Range | $50 M to 100M |
# of Employees | 435 |
Plant Area |
209,247
ft2
|
Annual Production | 18,324,088
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $337,213 | 6,330,303 |
kWh
|
$0.053 |
Electricity Demand | $181,065 | 15,293 |
kW-mo/yr
|
$11.84 |
Natural Gas | $134,556 | 28,723 |
MMBtu
|
$4.68 |
TOTAL YEARLY COSTS | $652,834 | |||
RECOMMENDED SAVINGS* | $97,953 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $53,022 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $86 | - |
$86
1,621
kWh
|
- | - | - | |
02 | 2.4322: Use or replace with energy efficient substitutes | $866 | - |
$664
12,483
kWh
|
$202
-
kW-mo/yr
|
- | - | |
03 | 4.821: Pay bills on time to avoid late fees | $828 | - | - | - | - | $828 | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $1,933 | $3 | - | - |
$1,933
-
MMBtu
|
- | |
05 | 2.6218: Turn off equipment when not in use | $24,829 | $2,670 | - | - |
$23,587
-
MMBtu
|
$1,242 | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $7,541 | $1,698 |
$5,219
98,100
kWh
|
$2,322
-
kW-mo/yr
|
- | - | |
07 | 2.7135: Install occupancy sensors | $3,769 | $3,724 |
$3,769
70,848
kWh
|
- | - | - | |
08 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $31,824 | $38,940 | - | - |
$31,824
-
MMBtu
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,194 | $19,486 |
$10,514
197,640
kWh
|
$4,680
-
kW-mo/yr
|
- | - | |
10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $134 | $270 |
$93
1,749
kWh
|
$41
-
kW-mo/yr
|
- | - | |
11 | 2.2437: Recover waste heat from equipment | $3,464 | $9,078 |
$(-45.0)
(-842)
kWh
|
$(-3.0)
-
kW-mo/yr
|
$3,512
-
MMBtu
|
- | |
12 | 2.3212: Optimize plant power factor | $7,316 | $21,686 | - | - | - | $7,316 | |
13 | 2.4221: Install compressor air intakes in coolest locations | $169 | $627 |
$103
1,941
kWh
|
$66
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $97,953 | $98,182 |
$20,403
383,540
kWh
|
$7,308
-
kW-mo/yr
|
$60,856
-
MMBtu
|
$9,386 | ||
TOTAL IMPLEMENTED | $53,022 | $47,836 |
$15,126
284,341
kWh
|
$4,923
-
kW-mo/yr
|
$23,587
-
MMBtu
|
$9,386 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs