Assessment Year 2016
Principal Product Automotive Parts
NAICS 336350: Motor Vehicle Transmission and Power Train Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $100
M
to 500
M
# of Employees 300
Plant Area 211,273
ft2
Annual Production 5,273,031
units
Production Hrs. Annual 8,400
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,304,796 22,845,960
kWh
Electricity Demand $326,704 40,274
kW-mo/yr
Electricity Fees $3,148 -
Natural Gas $78,600 10,641
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $342,664 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $110,930

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $7,775 $4 $7,057
123,803
kWh
$718
-
kW-mo/yr
- - -
02 2.4323: Use optimum size and capacity equipment $2,745 - $2,297
40,296
kWh
$448
-
kW-mo/yr
- - -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,196 $35 $2,196
38,528
kWh
- - - -
04 2.7224: Reduce space conditioning during non-working hours $931 $20 - - $931
-
MMBtu
- -
05 2.7135: Install occupancy sensors $5,310 $1,611 $5,310
93,154
kWh
- - - -
06 2.7232: Replace existing hvac unit with high efficiency model $9,664 $3,260 $5,054
88,667
kWh
$4,610
-
kW-mo/yr
- - -
07 2.4322: Use or replace with energy efficient substitutes $1,734 $760 $1,734
30,416
kWh
- - - -
08 3.5131: Recycle white water $61,804 $36,000 - - - $61,804
-
Tgal
-
09 4.631: Install an uninteruptable power supply $230,000 $251,000 - - - - $230,000
10 2.7142: Utilize higher efficiency lamps and/or ballasts $20,505 $75,569 $16,711
293,173
kWh
$3,794
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $342,664 $368,259 $40,359
708,037
kWh
$9,570
-
kW-mo/yr
$931
-
MMBtu
$61,804
-
Tgal
$230,000
TOTAL IMPLEMENTED $110,930 $116,499 $38,625
677,621
kWh
$9,570
-
kW-mo/yr
$931
-
MMBtu
$61,804
-
Tgal
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings