Assessment Year | 2015 |
---|---|
Principal Product | Baked Sweet Goods, Donuts |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $100 M to 500M |
# of Employees | 290 |
Plant Area |
231,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $382,709 | 7,352,800 |
kWh
|
$0.052 |
Electricity Demand | $160,221 | 14,204 |
kW-mo/yr
|
$11.28 |
Electricity Fees | $45,590 | - |
|
- |
Natural Gas | $279,414 | 43,694 |
MMBtu
|
$6.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $69,010 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,547 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,458 | $163 |
$11,458
220,355
kWh
|
- | - | - | - | |
02 | 2.7135: Install occupancy sensors | $2,848 | $798 |
$2,848
54,772
kWh
|
- | - | - | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,543 | $900 | - | - | - |
$2,543
-
MMBtu
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,968 | $623 |
$1,389
26,707
kWh
|
$579
-
kW-mo/yr
|
- | - | - | |
05 | 4.812: Apply for investment incentives | $30,801 | $10,000 | - | - | $30,801 | - | - | |
06 | 4.812: Apply for investment incentives | $10,288 | $5,000 | - | - | - | - | $10,288 | |
07 | 2.4221: Install compressor air intakes in coolest locations | $150 | $380 | - | - | - |
$150
-
MMBtu
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,755 | $20,898 |
$2,599
49,990
kWh
|
$1,156
-
kW-mo/yr
|
- | - | - | |
09 | 2.3212: Optimize plant power factor | $5,199 | $23,927 | - | - | $5,199 | - | - | |
TOTAL RECOMMENDED | $69,010 | $62,689 |
$18,294
351,824
kWh
|
$1,735
-
kW-mo/yr
|
$36,000 |
$2,693
-
MMBtu
|
$10,288 | ||
TOTAL IMPLEMENTED | $52,547 | $15,163 |
$11,458
220,355
kWh
|
- | $30,801 | - | $10,288 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs