Assessment Year 2014
Principal Product Hose Reels
NAICS 332912: Fluid Power Valve and Hose Fitting Manufacturing
SIC 3499: Fabricated Metal Products, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 200
Plant Area 134,106
ft2
Annual Production 4,200,000
pieces
Production Hrs. Annual 4,200
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $191,136 2,404,480
kWh
Electricity Demand $51,602 7,217
kW-mo/yr
Electricity Fees $2,766 -
Natural Gas $75,147 10,207
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $138,233 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $34,385

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings
01 2.7221: Lower temperature during the winter season and vice-versa $9,363 $210 $3,063
38,535
kWh
- $6,300
-
MMBtu
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,383 $92 $6,383
80,292
kWh
- - -
03 2.7135: Install occupancy sensors $980 $122 $980
12,326
kWh
- - -
04 3.6192: Use a less expensive method of waste removal $82,707 $12,435 - - - $82,707
-
lb
05 2.2511: Insulate bare equipment $2,997 $1,104 - - $2,997
-
MMBtu
-
06 2.4221: Install compressor air intakes in coolest locations $1,419 $512 $1,129
14,196
kWh
$290
-
kW-mo/yr
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $6,432 $4,014 $6,432
64,282
kWh
- - -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $27,953 $54,929 $22,141
278,527
kWh
$5,812
-
kW-mo/yr
- -
TOTAL RECOMMENDED $138,233 $73,418 $40,128
488,158
kWh
$6,102
-
kW-mo/yr
$9,297
-
MMBtu
$82,707
-
lb
TOTAL IMPLEMENTED $34,385 $58,943 $28,573
342,809
kWh
$5,812
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs