Assessment Year 2024
Principal Product Bubble and Protective Mailers
NAICS 326199: All Other Plastics Product Manufacturing
SIC 2671: Packaging Paper and Plastics Film, Coated and Laminated
Sales Range $50
M
to 100
M
# of Employees 96
Plant Area 145,000
ft2
Annual Production 100,000,000
units
Production Hrs. Annual 8,736
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $620,688 6,966,265
kWh
Electricity Demand $128,785 14,659
kW-mo/yr
Electricity Fees $29,623 -
Natural Gas $15,923 3,075
MMBtu
Waste Disposal Costs
Water Usage $4,245 335
Tgal
TOTAL YEARLY COSTS $799,265
RECOMMENDED SAVINGS* $171,683 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.9114: Use solar heat to make electricty $79,445 $420,971 $50,166
563,658
kWh
$29,280
-
kW-mo/yr
- -
02 4.631: Install an uninteruptable power supply $48,560 $367,354 - - - $48,560
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,007 $683 $886
9,959
kWh
$120
-
kW-mo/yr
- -
04 2.4239: Eliminate or reduce compressed air usage $6,527 - $6,454
72,512
kWh
$73
-
kW-mo/yr
- -
05 2.7221: Lower temperature during the winter season and vice-versa $3,076 - $2,229
25,045
kWh
$847
-
kW-mo/yr
- -
06 2.4239: Eliminate or reduce compressed air usage $2,212 $376 $294
3,305
kWh
$1,918
-
kW-mo/yr
- -
07 2.7232: Replace existing hvac unit with high efficiency model $3,800 $30,177 $3,332
37,418
kWh
$411
-
kW-mo/yr
$57
-
MMBtu
-
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,286 $160 $257
2,893
kWh
$1,028
-
kW-mo/yr
- -
09 2.4221: Install compressor air intakes in coolest locations $4,295 $652 $3,738
42,000
kWh
$557
-
kW-mo/yr
- -
10 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $17,150 $4,200 $15,056
169,169
kWh
$2,094
-
kW-mo/yr
- -
11 2.4322: Use or replace with energy efficient substitutes $4,325 $48,415 $1,837
20,641
kWh
$2,488
-
kW-mo/yr
- -
TOTAL RECOMMENDED $171,683 $872,989 $84,249
946,599
kWh
$38,817
-
kW-mo/yr
$57
-
MMBtu
$48,560
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs