Assessment Year | 2024 |
---|---|
Principal Product | Bubble and Protective Mailers |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
Sales Range | $50 M to 100M |
# of Employees | 96 |
Plant Area |
145,000
ft2
|
Annual Production | 100,000,000
units
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $620,688 | 6,966,265 |
kWh
|
$0.089 | |
Electricity Demand | $128,785 | 14,659 |
kW-mo/yr
|
$8.79 | |
Electricity Fees | $29,623 | - |
|
- | |
Natural Gas | $15,923 | 3,075 |
MMBtu
|
$5.18 | |
Waste Disposal Costs | |||||
Water Usage | $4,245 | 335 |
Tgal
|
$12.68 | |
TOTAL YEARLY COSTS | $799,265 | ||||
RECOMMENDED SAVINGS* | $171,683 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $79,445 | $420,971 |
$50,166
563,658
kWh
|
$29,280
-
kW-mo/yr
|
- | - | |
02 | 4.631: Install an uninteruptable power supply | $48,560 | $367,354 | - | - | - | $48,560 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,007 | $683 |
$886
9,959
kWh
|
$120
-
kW-mo/yr
|
- | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $6,527 | - |
$6,454
72,512
kWh
|
$73
-
kW-mo/yr
|
- | - | |
05 | 2.7221: Lower temperature during the winter season and vice-versa | $3,076 | - |
$2,229
25,045
kWh
|
$847
-
kW-mo/yr
|
- | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $2,212 | $376 |
$294
3,305
kWh
|
$1,918
-
kW-mo/yr
|
- | - | |
07 | 2.7232: Replace existing hvac unit with high efficiency model | $3,800 | $30,177 |
$3,332
37,418
kWh
|
$411
-
kW-mo/yr
|
$57
-
MMBtu
|
- | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,286 | $160 |
$257
2,893
kWh
|
$1,028
-
kW-mo/yr
|
- | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $4,295 | $652 |
$3,738
42,000
kWh
|
$557
-
kW-mo/yr
|
- | - | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,150 | $4,200 |
$15,056
169,169
kWh
|
$2,094
-
kW-mo/yr
|
- | - | |
11 | 2.4322: Use or replace with energy efficient substitutes | $4,325 | $48,415 |
$1,837
20,641
kWh
|
$2,488
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $171,683 | $872,989 |
$84,249
946,599
kWh
|
$38,817
-
kW-mo/yr
|
$57
-
MMBtu
|
$48,560 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs