Assessment Year 2024
Principal Product Electric Heaters
NAICS 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing
SIC 3822: Automatic Controls for Regulating Residential and Commercial Environments and Appliances
Sales Range $50
M
to 100
M
# of Employees 375
Plant Area 221,000
ft2
Annual Production 100,000
pieces
Production Hrs. Annual 4,420
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $255,099 3,828,976
kWh
Electricity Demand $140,110 13,149
kW-mo/yr
Electricity Fees $34,888 -
Natural Gas $155,234 27,141
MMBtu
TOTAL YEARLY COSTS $585,331
RECOMMENDED SAVINGS* $368,028 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.9114: Use solar heat to make electricty $274,832 $1,429,458 $140,835
2,102,020
kWh
$133,996
-
kW-mo/yr
-
02 2.6231: Utilize controls to operate equipment only when needed $22,099 $10,776 $22,099
329,832
kWh
- -
03 2.5122: Replace high resistance ducts, pipes, and fittings $2,629 $118 $1,836
27,404
kWh
$793
-
kW-mo/yr
-
04 2.4239: Eliminate or reduce compressed air usage $21,638 $33,160 $829
12,372
kWh
$20,810
-
kW-mo/yr
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,340 - $2,085
31,123
kWh
$1,255
-
kW-mo/yr
-
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $158 $432 $98
1,459
kWh
$60
-
kW-mo/yr
-
07 2.3191: Use demand controller or load shedder $1,874 $10,418 $1,089
16,249
kWh
- $785
-
MMBtu
08 2.2511: Insulate bare equipment $41,459 $20,803 $6,751
100,762
kWh
$2,916
-
kW-mo/yr
$31,791
-
MMBtu
TOTAL RECOMMENDED $368,028 $1,505,165 $175,622
2,621,221
kWh
$159,830
-
kW-mo/yr
$32,576
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs