ITAC Assessment: IC0298
ITAC logo
ITAC Assessment: IC0298
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Rubber and Plastic Seals for Automotives and RVs
NAICS 326299: All Other Rubber Product Manufacturing
SIC 3069: Fabricated Rubber Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 100
Plant Area 140,000
ft2
Annual Production 48,000
thousand feet
Production Hrs. Annual 4,160
hrs
Location (State) Indiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $201,603 2,381,008
kWh
Electricity Demand $101,334 8,312
kW-mo/yr
Electricity Fees $84,265 -
Natural Gas $11,825 1,027
MMBtu
Waste Disposal Costs
Water Usage $14,672 691
Tgal
TOTAL YEARLY COSTS $413,700
RECOMMENDED SAVINGS* $283,326 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4239: Eliminate or reduce compressed air usage $2,466 $2,200 $1,606
18,957
kWh
$860
-
kW-mo/yr
-
02 2.4239: Eliminate or reduce compressed air usage $19,913 $4,400 $14,281
168,605
kWh
$5,632
-
kW-mo/yr
-
03 2.7261: Install timers and/or thermostats $3,568 $280 $3,568
42,120
kWh
- -
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $14,618 $558 $10,330
121,955
kWh
$4,288
-
kW-mo/yr
-
05 2.9114: Use solar heat to make electricty $216,800 $1,202,971 $115,659
1,365,517
kWh
$101,140
-
kW-mo/yr
-
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,839 - $2,712
32,024
kWh
$1,126
-
kW-mo/yr
-
07 2.6212: Turn off equipment during breaks, reduce operating time $352 - $352
4,160
kWh
- -
08 2.7221: Lower temperature during the winter season and vice-versa $63 - $52
616
kWh
$10
-
kW-mo/yr
-
09 2.2511: Insulate bare equipment $259 $259 - - $259
-
MMBtu
10 2.2511: Insulate bare equipment $18,765 $12,716 $17,956
211,993
kWh
$809
-
kW-mo/yr
-
11 2.4323: Use optimum size and capacity equipment $2,685 $6,178 $1,840
21,718
kWh
$846
-
kW-mo/yr
-
TOTAL RECOMMENDED $283,326 $1,229,562 $168,355
1,987,666
kWh
$114,712
-
kW-mo/yr
$259
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings