| Assessment Year | 2024 |
|---|---|
| Principal Product | Rubber and Plastic Seals for Automotives and RVs |
| NAICS | 326299: All Other Rubber Product Manufacturing |
| SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
140,000
ft2
|
| Annual Production | 48,000
thousand feet
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $201,603 | 2,381,008 |
kWh
|
$0.085 | |
| Electricity Demand | $101,334 | 8,312 |
kW-mo/yr
|
$12.19 | |
| Electricity Fees | $84,265 | - |
|
- | |
| Natural Gas | $11,825 | 1,027 |
MMBtu
|
$11.51 | |
| Waste Disposal Costs | |||||
| Water Usage | $14,672 | 691 |
Tgal
|
$21.24 | |
| TOTAL YEARLY COSTS | $413,700 | ||||
| RECOMMENDED SAVINGS* | $283,326 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $42,611 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $2,466 | $2,200 |
$1,606
18,957
kWh
|
$860
-
kW-mo/yr
|
- | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $19,913 | $4,400 |
$14,281
168,605
kWh
|
$5,632
-
kW-mo/yr
|
- | |
| 03 | 2.7261: Install timers and/or thermostats | $3,568 | $280 |
$3,568
42,120
kWh
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $14,618 | $558 |
$10,330
121,955
kWh
|
$4,288
-
kW-mo/yr
|
- | |
| 05 | 2.9114: Use solar heat to make electricty | $216,800 | $1,202,971 |
$115,659
1,365,517
kWh
|
$101,140
-
kW-mo/yr
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,839 | - |
$2,712
32,024
kWh
|
$1,126
-
kW-mo/yr
|
- | |
| 07 | 2.6212: Turn off equipment during breaks, reduce operating time | $352 | - |
$352
4,160
kWh
|
- | - | |
| 08 | 2.7221: Lower temperature during the winter season and vice-versa | $63 | - |
$52
616
kWh
|
$10
-
kW-mo/yr
|
- | |
| 09 | 2.2511: Insulate bare equipment | $259 | $259 | - | - |
$259
-
MMBtu
|
|
| 10 | 2.2511: Insulate bare equipment | $18,765 | $12,716 |
$17,956
211,993
kWh
|
$809
-
kW-mo/yr
|
- | |
| 11 | 2.4323: Use optimum size and capacity equipment | $2,685 | $6,178 |
$1,840
21,718
kWh
|
$846
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $283,326 | $1,229,562 |
$168,355
1,987,666
kWh
|
$114,712
-
kW-mo/yr
|
$259
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $42,611 | $5,496 |
$31,295
369,481
kWh
|
$11,057
-
kW-mo/yr
|
$259
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs