ITAC Assessment: IC0286
ITAC logo
ITAC Assessment: IC0286
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Office Space
NAICS 551114: Corporate, Subsidiary, and Regional Managing Offices
SIC 6541: Title Abstract Offices
Sales Range less than $500
k
# of Employees 50
Plant Area 40,560
ft2
Annual Production 1
units
Production Hrs. Annual 2,574
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $42,618 463,200
kWh
Electricity Demand $18,934 1,493
kW-mo/yr
Electricity Fees $8,982 -
Natural Gas $14,146 1,659
MMBtu
TOTAL YEARLY COSTS $84,680
RECOMMENDED SAVINGS* $69,808 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,190

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7241: Install outside air damper / economizer on hvac unit $24,563 $10,218 $14,953
162,535
kWh
$9,610
-
kW-mo/yr
-
02 2.9114: Use solar heat to make electricty $26,775 $203,319 $22,463
244,168
kWh
$4,312
-
kW-mo/yr
-
03 3.1161: Eliminate/reduce an operation $5,835 - $3,552
38,610
kWh
$2,283
-
kW-mo/yr
-
04 2.6231: Utilize controls to operate equipment only when needed $796 - - - $796
-
MMBtu
05 2.7494: Install storm windows and doors $619 $7,463 $50
542
kWh
$85
-
kW-mo/yr
$485
-
MMBtu
06 2.7135: Install occupancy sensors $306 $388 $184
2,005
kWh
$121
-
kW-mo/yr
-
07 2.6218: Turn off equipment when not in use $254 - $71
772
kWh
$183
-
kW-mo/yr
-
08 2.7226: Use computer programs to optimize hvac performance $4,154 $4,776 $3,826
41,586
kWh
$328
-
kW-mo/yr
-
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,267 - $2,598
28,237
kWh
$1,670
-
kW-mo/yr
-
10 2.1224: Replace boiler $2,240 $49,894 - - $2,240
-
MMBtu
TOTAL RECOMMENDED $69,808 $276,058 $47,698
518,455
kWh
$18,590
-
kW-mo/yr
$3,520
-
MMBtu
TOTAL IMPLEMENTED $7,190 $388 $3,808
41,387
kWh
$2,587
-
kW-mo/yr
$796
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs