Assessment Year | 2023 |
---|---|
Principal Product | Commercial Lighting Fixtures |
NAICS | 335122: Commercial, Industrial, and Institutional Electric Lighting Fixture Manufacturing |
SIC | 3646: Commercial, Industrial, and Institutional Electric Lighting Fixtures |
Sales Range | $50 M to 100M |
# of Employees | 340 |
Plant Area |
180,000
ft2
|
Annual Production | 7,161,463
units
|
Production Hrs. Annual | 4,576
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $299,929 | 3,820,747 |
kWh
|
$0.079 | |
Electricity Fees | $151,169 | - |
|
- | |
Natural Gas | $388,997 | 46,948 |
MMBtu
|
$8.29 | |
Waste Disposal Costs | |||||
Water Usage | $37,499 | 3,362 |
Tgal
|
$11.15 | |
TOTAL YEARLY COSTS | $877,594 | ||||
RECOMMENDED SAVINGS* | $357,887 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $205,550 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,480 | $3,669 |
$6,480
82,029
kWh
|
- | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $4,864 | - |
$4,864
61,571
kWh
|
- | - | |
03 | 2.6127: Maintain air filters by cleaning or replacement | $445 | - |
$445
5,628
kWh
|
- | - | |
04 | 2.2511: Insulate bare equipment | $556 | $897 | - |
$556
-
MMBtu
|
- | |
05 | 2.5113: Use direct flame impingement or infrared processing for chamber type heating | $152,337 | $14,315 | - |
$152,337
-
MMBtu
|
- | |
06 | 4.231: Purchase equipment instead of leasing | $192,600 | $121,203 | - | - | $192,600 | |
07 | 2.6218: Turn off equipment when not in use | $415 | - |
$415
5,256
kWh
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $190 | $379 |
$190
2,406
kWh
|
- | - | |
TOTAL RECOMMENDED | $357,887 | $140,463 |
$12,394
156,891
kWh
|
$152,893
-
MMBtu
|
$192,600 | ||
TOTAL IMPLEMENTED | $205,550 | $126,148 |
$12,394
156,891
kWh
|
$556
-
MMBtu
|
$192,600 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs