| Assessment Year | 2023 |
|---|---|
| Principal Product | Forged and Casted Rolls |
| NAICS | 332811: Metal Heat Treating |
| SIC | 3398: Metal Heat Treating |
| Sales Range | $50 M to 100M |
| # of Employees | 87 |
| Plant Area |
100,000
ft2
|
| Annual Production | 2,000
units
|
| Production Hrs. Annual | 6,656
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $546,221 | 7,244,736 |
kWh
|
$0.075 |
| Electricity Demand | $438,552 | 33,755 |
kW-mo/yr
|
$12.99 |
| Electricity Fees | $198,145 | - |
|
- |
| Natural Gas | $161,752 | 24,630 |
MMBtu
|
$6.57 |
| TOTAL YEARLY COSTS | $1,344,670 | |||
| RECOMMENDED SAVINGS* | $136,486 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $1,479 | $985 | - | - |
$1,479
-
MMBtu
|
|
| 02 | 2.4221: Install compressor air intakes in coolest locations | $2,480 | $823 |
$1,918
23,978
kWh
|
$562
-
kW-mo/yr
|
- | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $5,724 | $433 |
$3,127
39,092
kWh
|
$2,597
-
kW-mo/yr
|
- | |
| 04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $137 | $337 | - | - |
$137
-
MMBtu
|
|
| 05 | 2.9114: Use solar heat to make electricty | $121,502 | $1,271,713 |
$112,517
1,406,464
kWh
|
$8,985
-
kW-mo/yr
|
- | |
| 06 | 2.2511: Insulate bare equipment | $5,165 | $8,778 |
$5,165
64,565
kWh
|
- | - | |
| TOTAL RECOMMENDED | $136,486 | $1,283,069 |
$122,727
1,534,099
kWh
|
$12,144
-
kW-mo/yr
|
$1,615
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs