Assessment Year | 2022 |
---|---|
Principal Product | Farming Augers |
NAICS | 332216: Saw Blade and Handtool Manufacturing |
SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
110,000
ft2
|
Annual Production | 35,000
units
|
Production Hrs. Annual | 6,864
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $50,065 | 1,274,844 |
kWh
|
$0.039 | |
Electricity Demand | $86,043 | 3,469 |
kW-mo/yr
|
$24.80 | |
Electricity Fees | $18,569 | - |
|
- | |
Natural Gas | $71,114 | 8,058 |
MMBtu
|
$8.83 | |
Waste Disposal Costs | |||||
Water Usage | $2,754 | 226 |
Tgal
|
$12.19 | |
Water Disposal | $3,428 | 249 |
Tgal
|
$13.76 | |
TOTAL YEARLY COSTS | $231,974 | ||||
RECOMMENDED SAVINGS* | $19,192 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $7,955 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $5,084 | $2,113 |
$(-27.0)
(-695)
kWh
|
$(-38.9)
-
kW-mo/yr
|
- |
$5,150
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,944 | $4,150 |
$1,856
47,234
kWh
|
$2,088
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,361 | $10,377 |
$1,123
28,561
kWh
|
$1,238
-
kW-mo/yr
|
- | - | |
04 | 2.4224: Upgrade controls on compressors | $2,600 | $15,017 |
$1,231
31,574
kWh
|
$1,369
-
kW-mo/yr
|
- | - | |
05 | 2.3212: Optimize plant power factor | $3,552 | $15,893 | - | - | $3,552 | - | |
06 | 2.7314: Reduce ventilation air | $1,650 | $6,000 | - | - | - |
$1,650
-
MMBtu
|
|
TOTAL RECOMMENDED | $19,192 | $53,551 |
$4,183
106,674
kWh
|
$4,656
-
kW-mo/yr
|
$3,552 |
$6,800
-
MMBtu
|
||
TOTAL IMPLEMENTED | $7,955 | $20,527 |
$2,979
75,795
kWh
|
$3,326
-
kW-mo/yr
|
- |
$1,650
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs