ITAC Assessment: IC0242
ITAC logo
ITAC Assessment: IC0242
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2020
Principal Product Can Lids
NAICS 332431: Metal Can Manufacturing
SIC 3411: Metal Cans
Sales Range $50
M
to 100
M
# of Employees 200
Plant Area 340,000
ft2
Annual Production 2,000,000,000
units
Production Hrs. Annual 8,760
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $917,141 16,090,200
kWh
Electricity Demand $482,362 32,159
kW-mo/yr
Electricity Fees $70,751 -
Natural Gas $464,969 139,057
MMBtu
Waste Disposal Costs
Water Usage $16,253 1,417
Tgal
TOTAL YEARLY COSTS $1,951,476
RECOMMENDED SAVINGS* $86,012 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $48,538 $5,100 $35,110
585,162
kWh
$13,428
-
kW-mo/yr
-
02 2.4221: Install compressor air intakes in coolest locations $4,255 $10,230 $3,080
51,327
kWh
$1,176
-
kW-mo/yr
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $8,050 $2,715 $8,050
134,159
kWh
- -
04 2.6212: Turn off equipment during breaks, reduce operating time $1,839 - - - $1,839
-
MMBtu
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $13,675 $4,640 $10,318
171,973
kWh
$3,357
-
kW-mo/yr
-
06 2.3132: Recharge batteries on during off-peak demand periods $9,655 - - $9,655
-
kW-mo/yr
-
TOTAL RECOMMENDED $86,012 $22,685 $56,557
942,621
kWh
$27,616
-
kW-mo/yr
$1,839
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs