| Assessment Year | 2019 |
|---|---|
| Principal Product | Food Packaging Products |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 47 |
| Plant Area |
71,920
ft2
|
| Annual Production | 6,000,000
lb
|
| Production Hrs. Annual | 8,600
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $523,530 | 5,816,998 |
kWh
|
$0.090 |
| Electricity Demand | $111,103 | 26,390 |
kW-mo/yr
|
$4.21 |
| Natural Gas | $12,491 | 2,070 |
MMBtu
|
$6.03 |
| TOTAL YEARLY COSTS | $647,124 | |||
| RECOMMENDED SAVINGS* | $191,628 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $156,049 | $91,000 |
$189,783
2,108,700
kWh
|
$12,504
-
kW-mo/yr
|
$(-46,238.0)
-
MMBtu
|
|
| 02 | 2.6231: Utilize controls to operate equipment only when needed | $15,726 | $8,414 |
$15,726
174,730
kWh
|
- | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $8,962 | $2,550 |
$8,424
93,589
kWh
|
$538
-
kW-mo/yr
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,892 | $3,797 |
$10,061
111,763
kWh
|
$831
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $191,628 | $105,761 |
$223,994
2,488,782
kWh
|
$13,872
-
kW-mo/yr
|
$(-46,238.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs