Assessment Year | 2017 |
---|---|
Principal Product | Steel Forgings for the Auto Industry |
NAICS | 331410: Nonferrous Metal (except Aluminum) Smelting and Refining |
SIC | 3542: Machine Tools, Metal Forming Types |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
75,000
ft2
|
Annual Production | 4,000,000
units
|
Production Hrs. Annual | 5,110
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $905,847 | 10,942,512 |
kWh
|
$0.083 |
Natural Gas | $35,769 | 4,413 |
MMBtu
|
$8.11 |
TOTAL YEARLY COSTS | $941,616 | |||
RECOMMENDED SAVINGS* | $102,963 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,956 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $73,989 | - | - | $73,989 | - | |
02 | 2.7221: Lower temperature during the winter season and vice-versa | $3,956 | - | - | - |
$3,956
-
MMBtu
|
|
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,843 | $50 |
$1,843
22,950
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $3,015 | $280 |
$3,015
37,665
kWh
|
- | - | |
05 | 2.4133: Use most efficient type of electric motors | $20,160 | $4,186 |
$20,160
352,817
kWh
|
- | - | |
TOTAL RECOMMENDED | $102,963 | $4,516 |
$25,018
413,432
kWh
|
$73,989 |
$3,956
-
MMBtu
|
||
TOTAL IMPLEMENTED | $3,956 | - | - | - |
$3,956
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs