ITAC Assessment: IC0189
ITAC logo
ITAC Assessment: IC0189
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2011
Principal Product Axles & Driveline Products
NAICS 336350: Motor Vehicle Transmission and Power Train Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $5
M
to 10
M
# of Employees 200
Plant Area 610,000
ft2
Annual Production 7,500
pieces
Production Hrs. Annual 4,233
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $256,196 5,414,038
kWh
Electricity Demand $79,019 10,188
kW-mo/yr
Electricity Fees $32,483 -
Natural Gas $288,948 38,422
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $176,979 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $176,685

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Ancillary Material Cost Savings
01 2.7221: Lower temperature during the winter season and vice-versa $2,166 - - - $2,166
-
MMBtu
- -
02 2.7233: Use properly designed and sized hvac equipment $156,506 $686,583 - - $156,506
-
MMBtu
- -
03 2.4321: Upgrade obsolete equipment $12,266 $100,000 - - $12,266
-
MMBtu
- -
04 2.4221: Install compressor air intakes in coolest locations $1,263 $1,142 $1,030
21,914
kWh
$233
-
kW-mo/yr
- - -
05 2.6218: Turn off equipment when not in use $4,441 $382 $4,441
94,494
kWh
- - - -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $43 $58 $9
175
kWh
$2
-
kW-mo/yr
- $10 $22
07 2.6211: Conserve energy by efficient use of vending machines $294 - $240
5,100
kWh
$54
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $176,979 $788,165 $5,720
121,683
kWh
$289
-
kW-mo/yr
$170,938
-
MMBtu
$10 $22
TOTAL IMPLEMENTED $176,685 $788,165 $5,480
116,583
kWh
$235
-
kW-mo/yr
$170,938
-
MMBtu
$10 $22
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs