Assessment Year | 2010 |
---|---|
Principal Product | Corrugated Boxes |
NAICS | 322211: Corrugated and Solid Fiber Box Manufacturing |
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
132,000
ft2
|
Annual Production | 409,918
thousand feet
|
Production Hrs. Annual | 4,352
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $105,205 | 1,017,000 |
kWh
|
$0.10 |
Electricity Demand | $87,966 | 6,732 |
kW-mo/yr
|
$13.07 |
Natural Gas | $15,018 | 1,750 |
MMBtu
|
$8.58 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,577 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,949 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $317 | $1,315 |
$188
3,120
kWh
|
$129
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,215 | $441 |
$361
3,508
kWh
|
$63
-
kW-mo/yr
|
- | - | $256 | $535 | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,067 | $1,035 |
$1,067
10,357
kWh
|
- | - | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $880 | $519 |
$652
6,336
kWh
|
$228
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7224: Reduce space conditioning during non-working hours | $858 | - | - | - |
$858
-
MMBtu
|
- | - | - | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $7,358 | $5,900 |
$5,642
94,030
kWh
|
$2,771
-
kW-mo/yr
|
$(-1,055.0)
-
MMBtu
|
- | - | - | |
07 | 2.1321: Replace fossil fuel equipment with electrical equipment | $8,677 | $40,071 |
$(-917.0)
(-15,276)
kWh
|
$(-333.0)
-
kW-mo/yr
|
- |
$9,298
-
MMBtu
|
$629 | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $205 | - |
$175
1,700
kWh
|
$30
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $20,577 | $49,281 |
$7,168
103,775
kWh
|
$2,888
-
kW-mo/yr
|
$(-197.0)
-
MMBtu
|
$9,298
-
MMBtu
|
$885 | $535 | ||
TOTAL IMPLEMENTED | $9,949 | $41,106 |
$325
(-3,219)
kWh
|
$(-303.0)
-
kW-mo/yr
|
- |
$9,298
-
MMBtu
|
$629 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs