ITAC Assessment: IC0158
ITAC logo
ITAC Assessment: IC0158
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2009
Principal Product Flat Rolled Carbon
NAICS 423510: Metal Service Centers and Other Metal Merchant Wholesalers
SIC 5051: Metals Service Centers and Offices
Sales Range $50
M
to 100
M
# of Employees 40
Plant Area 88,525
ft2
Annual Production 80,000
ton
Production Hrs. Annual 3,514
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $108,658 1,247,676
kWh
Electricity Demand $19,298 3,759
kW-mo/yr
Electricity Fees $4,480 -
Natural Gas $85,523 8,368
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $13,285 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,824

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $393 $686 $128
1,472
kWh
$10
-
kW-mo/yr
- $111 $144
02 2.7124: Make a practice of turning off lights when not needed $177 - $147
1,687
kWh
$30
-
kW-mo/yr
- - -
03 2.6218: Turn off equipment when not in use $2,880 - $2,397
27,547
kWh
$483
-
kW-mo/yr
- - -
04 2.4231: Reduce the pressure of compressed air to the minimum required $196 - $196
2,255
kWh
- - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,265 $1,495 $4,265
49,020
kWh
- - - -
06 2.6125: Keep equipment clean $2,325 - - - $2,565
-
MMBtu
$(-240.0) -
07 2.7442: Keep doors and windows shut when not on use $2,800 - - - $2,800
-
MMBtu
- -
08 2.6211: Conserve energy by efficient use of vending machines $249 - $157
1,800
kWh
$92
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $13,285 $2,181 $7,290
83,781
kWh
$615
-
kW-mo/yr
$5,365
-
MMBtu
$(-129.0) $144
TOTAL IMPLEMENTED $8,824 $686 $2,829
32,506
kWh
$615
-
kW-mo/yr
$5,365
-
MMBtu
$(-129.0) $144
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs