Assessment Year | 2009 |
---|---|
Principal Product | Flat Rolled Carbon |
NAICS | 423510: Metal Service Centers and Other Metal Merchant Wholesalers |
SIC | 5051: Metals Service Centers and Offices |
Sales Range | $50 M to 100M |
# of Employees | 40 |
Plant Area |
88,525
ft2
|
Annual Production | 80,000
ton
|
Production Hrs. Annual | 3,514
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $108,658 | 1,247,676 |
kWh
|
$0.087 |
Electricity Demand | $19,298 | 3,759 |
kW-mo/yr
|
$5.13 |
Electricity Fees | $4,480 | - |
|
- |
Natural Gas | $85,523 | 8,368 |
MMBtu
|
$10.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,285 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,824 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $393 | $686 |
$128
1,472
kWh
|
$10
-
kW-mo/yr
|
- | $111 | $144 | |
02 | 2.7124: Make a practice of turning off lights when not needed | $177 | - |
$147
1,687
kWh
|
$30
-
kW-mo/yr
|
- | - | - | |
03 | 2.6218: Turn off equipment when not in use | $2,880 | - |
$2,397
27,547
kWh
|
$483
-
kW-mo/yr
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $196 | - |
$196
2,255
kWh
|
- | - | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,265 | $1,495 |
$4,265
49,020
kWh
|
- | - | - | - | |
06 | 2.6125: Keep equipment clean | $2,325 | - | - | - |
$2,565
-
MMBtu
|
$(-240.0) | - | |
07 | 2.7442: Keep doors and windows shut when not on use | $2,800 | - | - | - |
$2,800
-
MMBtu
|
- | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $249 | - |
$157
1,800
kWh
|
$92
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $13,285 | $2,181 |
$7,290
83,781
kWh
|
$615
-
kW-mo/yr
|
$5,365
-
MMBtu
|
$(-129.0) | $144 | ||
TOTAL IMPLEMENTED | $8,824 | $686 |
$2,829
32,506
kWh
|
$615
-
kW-mo/yr
|
$5,365
-
MMBtu
|
$(-129.0) | $144 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs