| Assessment Year | 2009 |
|---|---|
| Principal Product | Flat Rolled Carbon |
| NAICS | 423510: Metal Service Centers and Other Metal Merchant Wholesalers |
| SIC | 5051: Metals Service Centers and Offices |
| Sales Range | $50 M to 100M |
| # of Employees | 40 |
| Plant Area |
88,525
ft2
|
| Annual Production | 80,000
ton
|
| Production Hrs. Annual | 3,514
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $108,658 | 1,247,676 |
kWh
|
$0.087 |
| Electricity Demand | $19,298 | 3,759 |
kW-mo/yr
|
$5.13 |
| Electricity Fees | $4,480 | - |
|
- |
| Natural Gas | $85,523 | 8,368 |
MMBtu
|
$10.22 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,285 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,824 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $393 | $686 |
$128
1,472
kWh
|
$10
-
kW-mo/yr
|
- | $111 | $144 | |
| 02 | 2.7124: Make a practice of turning off lights when not needed | $177 | - |
$147
1,687
kWh
|
$30
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $2,880 | - |
$2,397
27,547
kWh
|
$483
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $196 | - |
$196
2,255
kWh
|
- | - | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,265 | $1,495 |
$4,265
49,020
kWh
|
- | - | - | - | |
| 06 | 2.6125: Keep equipment clean | $2,325 | - | - | - |
$2,565
-
MMBtu
|
$(-240.0) | - | |
| 07 | 2.7442: Keep doors and windows shut when not on use | $2,800 | - | - | - |
$2,800
-
MMBtu
|
- | - | |
| 08 | 2.6211: Conserve energy by efficient use of vending machines | $249 | - |
$157
1,800
kWh
|
$92
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $13,285 | $2,181 |
$7,290
83,781
kWh
|
$615
-
kW-mo/yr
|
$5,365
-
MMBtu
|
$(-129.0) | $144 | ||
| TOTAL IMPLEMENTED | $8,824 | $686 |
$2,829
32,506
kWh
|
$615
-
kW-mo/yr
|
$5,365
-
MMBtu
|
$(-129.0) | $144 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs