| Assessment Year | 2007 |
|---|---|
| Principal Product | Manufacture aerial equipment |
| NAICS | 336211: Motor Vehicle Body Manufacturing |
| SIC | 3713: Truck and Bus Bodies |
| Sales Range | $50 M to 100M |
| # of Employees | 20 |
| Plant Area |
95,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 4,722
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $128,548 | 1,459,600 |
kWh
|
$0.088 |
| Electricity Demand | $48,396 | 3,984 |
kW-mo/yr
|
$12.15 |
| Natural Gas | $116,602 | 10,536 |
MMBtu
|
$11.07 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $29,221 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $28,038 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7141: Lower light fixtures in high ceiling areas | $14,537 | $81,554 |
$11,957
221,434
kWh
|
$2,580
-
kW-mo/yr
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,611 | $1,035 |
$2,611
48,356
kWh
|
- | - | |
| 03 | 2.4323: Use optimum size and capacity equipment | $1,183 | $4,040 |
$1,183
21,900
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,613 | $22,008 |
$3,035
56,215
kWh
|
$2,578
-
kW-mo/yr
|
- | |
| 05 | 2.4224: Upgrade controls on compressors | $561 | - |
$561
10,385
kWh
|
- | - | |
| 06 | 2.7141: Lower light fixtures in high ceiling areas | $2,946 | $2,902 |
$701
12,982
kWh
|
$219
-
kW-mo/yr
|
$2,026 | |
| 07 | 2.7135: Install occupancy sensors | $506 | $1,782 |
$433
8,012
kWh
|
$73
-
kW-mo/yr
|
- | |
| 08 | 2.4133: Use most efficient type of electric motors | $1,264 | - |
$389
7,200
kWh
|
$875
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $29,221 | $113,321 |
$20,870
386,484
kWh
|
$6,325
-
kW-mo/yr
|
$2,026 | ||
| TOTAL IMPLEMENTED | $28,038 | $109,281 |
$19,687
364,584
kWh
|
$6,325
-
kW-mo/yr
|
$2,026 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs