ITAC Assessment: IC0129
ITAC logo
ITAC Assessment: IC0129
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2007
Principal Product Manufacture aerial equipment
NAICS 336211: Motor Vehicle Body Manufacturing
SIC 3713: Truck and Bus Bodies
Sales Range $50
M
to 100
M
# of Employees 20
Plant Area 95,000
ft2
Annual Production 1
units
Production Hrs. Annual 4,722
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $128,548 1,459,600
kWh
Electricity Demand $48,396 3,984
kW-mo/yr
Natural Gas $116,602 10,536
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $29,221 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $28,038

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7141: Lower light fixtures in high ceiling areas $14,537 $81,554 $11,957
221,434
kWh
$2,580
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,611 $1,035 $2,611
48,356
kWh
- -
03 2.4323: Use optimum size and capacity equipment $1,183 $4,040 $1,183
21,900
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $5,613 $22,008 $3,035
56,215
kWh
$2,578
-
kW-mo/yr
-
05 2.4224: Upgrade controls on compressors $561 - $561
10,385
kWh
- -
06 2.7141: Lower light fixtures in high ceiling areas $2,946 $2,902 $701
12,982
kWh
$219
-
kW-mo/yr
$2,026
07 2.7135: Install occupancy sensors $506 $1,782 $433
8,012
kWh
$73
-
kW-mo/yr
-
08 2.4133: Use most efficient type of electric motors $1,264 - $389
7,200
kWh
$875
-
kW-mo/yr
-
TOTAL RECOMMENDED $29,221 $113,321 $20,870
386,484
kWh
$6,325
-
kW-mo/yr
$2,026
TOTAL IMPLEMENTED $28,038 $109,281 $19,687
364,584
kWh
$6,325
-
kW-mo/yr
$2,026
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings