| Assessment Year | 2006 |
|---|---|
| Principal Product | poultry processing |
| NAICS | 311615: Poultry Processing |
| SIC | 2015: Poultry Slaughtering and Processing |
| Sales Range | $10 M to 50M |
| # of Employees | 192 |
| Plant Area |
93,493
ft2
|
| Annual Production | 15,000,000
pieces
|
| Production Hrs. Annual | 4,580
hrs
|
| Location (State) | Indiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $579,774 | 17,096,688 |
kWh
|
$0.034 |
| Electricity Demand | $304,821 | 37,146 |
kW-mo/yr
|
$8.21 |
| Electricity Fees | $3,806 | - |
|
- |
| Natural Gas | $735,234 | 80,916 |
MMBtu
|
$9.09 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $320,099 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $177,740 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,445 | $26,134 |
$3,183
93,615
kWh
|
$2,011
-
kW-mo/yr
|
- | $134 | $2,117 | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $3,985 | $16,831 |
$2,416
71,088
kWh
|
$1,569
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,680 | $65,036 |
$5,181
152,385
kWh
|
$3,276
-
kW-mo/yr
|
- | $436 | $2,787 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $272 | $420 |
$103
3,023
kWh
|
$66
-
kW-mo/yr
|
- | $126 | $(-23.0) | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $159 | $380 |
$58
1,720
kWh
|
$16
-
kW-mo/yr
|
- | $23 | $62 | - | |
| 06 | 2.4223: Install direct acting units in place of compressed air pressure system in safety system | $54 | $284 |
$21
617
kWh
|
$33
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.4322: Use or replace with energy efficient substitutes | $142,200 | $195,625 | - | - | - | - | - | $142,200 | |
| 08 | 2.1224: Replace boiler | $125,042 | $193,200 | - | - |
$125,042
-
MMBtu
|
- | - | - | |
| 09 | 2.2162: Reduce excess steam bleeding | $29,262 | $5,000 | - | - |
$29,262
-
MMBtu
|
- | - | - | |
| TOTAL RECOMMENDED | $320,099 | $502,910 |
$10,962
322,448
kWh
|
$6,971
-
kW-mo/yr
|
$154,304
-
MMBtu
|
$719 | $4,943 | $142,200 | ||
| TOTAL IMPLEMENTED | $177,740 | $306,905 |
$10,904
320,728
kWh
|
$6,955
-
kW-mo/yr
|
$154,304
-
MMBtu
|
$696 | $4,881 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs