ITAC Assessment: IC0087
ITAC logo
ITAC Assessment: IC0087
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product photo, pharmaceutical and good grade gelatine
NAICS 325510: Paint and Coating Manufacturing
SIC 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 72
Plant Area 200,000
ft2
Annual Production 8,200,000
lb
Production Hrs. Annual 8,592
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $344,743 10,483,713
kWh
Electricity Demand $144,617 17,426
kW-mo/yr
Electricity Fees $174,683 -
Natural Gas $1,401,734 244,220
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $732,921 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $304,849

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings Water Consumption Savings
01 2.2127: Flash condensate to produce lower pressure steam $210,887 $2,078 - - $195,613
-
MMBtu
- - - $15,274
-
Tgal
02 2.2191: Substitute hot process fluids for steam $135,849 $18,578 - - $135,849
-
MMBtu
- - - -
03 2.2427: Use waste heat from hot flue gases to preheat incoming fluids $216,557 $4,311 $(-1,998.0)
(-45,402)
kWh
$(-523.0)
-
kW-mo/yr
$215,411
-
MMBtu
- - $3,667 -
04 2.2414: Use waste heat from hot flue gases to preheat $43,578 $6,900 - - $43,578
-
MMBtu
- - - -
05 2.3321: Use steam pressure reduction to generate power $53,985 $1,560 $39,949
1,997,265
kWh
$22,709
-
kW-mo/yr
- $(-8,673.0) - - -
06 2.2414: Use waste heat from hot flue gases to preheat $14,571 $8,465 $(-4,266.0)
(-96,947)
kWh
$(-1,104.0)
-
kW-mo/yr
$19,941
-
MMBtu
- - - -
07 2.2511: Insulate bare equipment $28,383 $56,925 - - $28,383
-
MMBtu
- - - -
08 2.6231: Utilize controls to operate equipment only when needed $4,114 $609,500 $2,280
51,822
kWh
$1,834
-
kW-mo/yr
- - - - -
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $14,613 $104,650 $11,566
262,859
kWh
$3,047
-
kW-mo/yr
- - - - -
10 2.4133: Use most efficient type of electric motors $1,168 $79,350 $924
21,024
kWh
$244
-
kW-mo/yr
- - - - -
11 2.7141: Lower light fixtures in high ceiling areas $8,624 $332,143 $5,401
122,646
kWh
$1,795
-
kW-mo/yr
- - $859 $569 -
12 2.7141: Lower light fixtures in high ceiling areas $592 $174,800 $255
5,125
kWh
$59
-
kW-mo/yr
- - $114 $164 -
TOTAL RECOMMENDED $732,921 $1,399,260 $54,111
2,318,392
kWh
$28,061
-
kW-mo/yr
$638,775
-
MMBtu
$(-8,673.0) $973 $4,400 $15,274
-
Tgal
TOTAL IMPLEMENTED $304,849 $330,751 $(-5,085.0)
(-116,200)
kWh
$(-1,324.0)
-
kW-mo/yr
$307,313
-
MMBtu
- $114 $3,831 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs