Assessment Year | 2002 |
---|---|
Principal Product | Electrical Appliance Components |
NAICS |
n/a
|
SIC | 3639: Household Appliances, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
700,000
ft2
|
Annual Production | 3,500,000
pieces
|
Production Hrs. Annual | 5,640
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $458,704 | 7,774,645 |
kWh
|
$0.059 |
Electricity Demand | $71,806 | 21,215 |
kW-mo/yr
|
$3.38 |
Electricity Fees | $530,510 | - |
|
- |
Natural Gas | $501,477 | 75,791 |
MMBtu
|
$6.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $66,512 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,451 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,772 | $5,500 |
$3,783
64,206
kWh
|
$989
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,477 | - |
$2,208
37,421
kWh
|
$269
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.3132: Recharge batteries on during off-peak demand periods | $1,720 | - | - |
$1,400
-
kW-mo/yr
|
$320 | - | - | - | - | |
04 | 2.7135: Install occupancy sensors | $1,202 | $1,929 |
$1,135
19,237
kWh
|
$67
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $818 | $975 |
$295
4,993
kWh
|
$23
-
kW-mo/yr
|
- | - | $200 | - | $300 | |
06 | 2.7261: Install timers and/or thermostats | $407 | $145 |
$407
6,904
kWh
|
- | - | - | - | - | - | |
07 | 2.7261: Install timers and/or thermostats | $1,160 | $435 |
$1,160
19,655
kWh
|
- | - | - | - | - | - | |
08 | 2.7293: Install dry sprinkler system or other method to reduce heating requirements | $53,956 | $110,000 |
$(-2,060.0)
(-34,913)
kWh
|
- | - |
$98,016
-
MMBtu
|
- | $(-42,000.0) | - | |
TOTAL RECOMMENDED | $66,512 | $118,984 |
$6,928
117,503
kWh
|
$2,748
-
kW-mo/yr
|
$320 |
$98,016
-
MMBtu
|
$200 | $(-42,000.0) | $300 | ||
TOTAL IMPLEMENTED | $8,451 | $7,429 |
$7,126
120,864
kWh
|
$1,325
-
kW-mo/yr
|
- | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs