Assessment Year | 2001 |
---|---|
Principal Product | Forged Steel |
NAICS |
n/a
|
SIC | 3462: Iron and Steel Forgings |
Sales Range | $10 M to 50M |
# of Employees | 64 |
Plant Area |
100,000
ft2
|
Annual Production | 14,000,000
lb
|
Production Hrs. Annual | 2,295
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $66,484 | 2,116,189 |
kWh
|
$0.031 |
Electricity Demand | $74,394 | 6,115 |
kW-mo/yr
|
$12.17 |
Electricity Fees | $17,179 | - |
|
- |
Natural Gas | $865,822 | 203,418 |
MMBtu
|
$4.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,970 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,973 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,265 | $1,530 |
$2,947
75,557
kWh
|
$4,318
-
kW-mo/yr
|
- | - | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $160 | $150 |
$61
1,563
kWh
|
$99
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $444 | $968 |
$107
2,754
kWh
|
$46
-
kW-mo/yr
|
- | $217 | $74 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,536 | $9,420 |
$817
20,939
kWh
|
$708
-
kW-mo/yr
|
- | $11 | - | |
05 | 2.7135: Install occupancy sensors | $857 | $907 |
$710
18,214
kWh
|
$147
-
kW-mo/yr
|
- | - | - | |
06 | 2.2136: Install / repair insulation on steam lines | $12,728 | $6,351 | - | - |
$12,728
-
MMBtu
|
- | - | |
07 | 2.2136: Install / repair insulation on steam lines | $1,980 | $5,760 | - | - |
$1,980
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $24,970 | $25,086 |
$4,642
119,027
kWh
|
$5,318
-
kW-mo/yr
|
$14,708
-
MMBtu
|
$228 | $74 | ||
TOTAL IMPLEMENTED | $21,973 | $13,641 |
$2,947
75,557
kWh
|
$4,318
-
kW-mo/yr
|
$14,708
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs