| Assessment Year | 2001 |
|---|---|
| Principal Product | Refrigeration Equipment |
| NAICS |
n/a
|
| SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 300 |
| Plant Area |
285,685
ft2
|
| Annual Production | 24,000
pieces
|
| Production Hrs. Annual | 5,344
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $148,832 | 3,786,037 |
kWh
|
$0.039 |
| Electricity Demand | $105,425 | 8,652 |
kW-mo/yr
|
$12.19 |
| Electricity Fees | $16,877 | - |
|
- |
| Natural Gas | $58,913 | 16,038 |
MMBtu
|
$3.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,429,285 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $339,925 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $3,732 | - | - | - |
$3,732
-
MMBtu
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $14,032 | $700 |
$8,245
211,414
kWh
|
$5,787
-
kW-mo/yr
|
- | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $2,387 | $2,500 |
$1,403
35,976
kWh
|
$984
-
kW-mo/yr
|
- | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $855 | - |
$502
12,874
kWh
|
$353
-
kW-mo/yr
|
- | - | |
| 05 | 2.7135: Install occupancy sensors | $1,478 | $3,204 |
$533
13,670
kWh
|
$945
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $228 | $1,370 |
$160
4,107
kWh
|
$68
-
kW-mo/yr
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,986 | $68,895 |
$8,918
228,660
kWh
|
$7,068
-
kW-mo/yr
|
- | - | |
| 08 | 2.4133: Use most efficient type of electric motors | $1,227 | $3,266 |
$600
15,372
kWh
|
$627
-
kW-mo/yr
|
- | - | |
| 09 | 4.513: Re-arrange equipment layout to reduce labor costs | $110,160 | $64 | - | - | - | $110,160 | |
| 10 | 4.112: Replace old machine with new automatic multi-station tool | $367,200 | $826,000 | - | - | - | $367,200 | |
| 11 | 4.112: Replace old machine with new automatic multi-station tool | $612,000 | $900,000 | - | - | - | $612,000 | |
| 12 | 4.631: Install an uninteruptable power supply | $300,000 | $840,000 | - | - | - | $300,000 | |
| TOTAL RECOMMENDED | $1,429,285 | $2,645,999 |
$20,361
522,073
kWh
|
$15,832
-
kW-mo/yr
|
$3,732
-
MMBtu
|
$1,389,360 | ||
| TOTAL IMPLEMENTED | $339,925 | $919,935 |
$20,361
522,073
kWh
|
$15,832
-
kW-mo/yr
|
$3,732
-
MMBtu
|
$300,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs