ITAC Assessment: IA0507
ITAC logo
ITAC Assessment: IA0507
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2013
Principal Product Spray Dried Porcine Product
NAICS 311611: Animal (except Poultry) Slaughtering
SIC 2048: Prepared Feed and Feed Ingredients for Animals and Fowls, Except Dogs and Cats
Sales Range $10
M
to 50
M
# of Employees 33
Plant Area 50,551
ft2
Annual Production 18,500,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $298,828 3,626,520
kWh
Electricity Demand $89,000 10,476
kW-mo/yr
Natural Gas $390,799 80,992
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $68,682 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $67,340

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $8,483 $4,993 $7,280
74,131
kWh
$1,203
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $1,279 $1,198 $1,098
13,328
kWh
$181
-
kW-mo/yr
-
03 2.7135: Install occupancy sensors $2,933 $2,826 $2,933
35,584
kWh
- -
04 2.2511: Insulate bare equipment $9,686 $7,803 - - $9,686
-
MMBtu
05 2.1233: Analyze flue gas for proper air/fuel ratio $13,342 $1,000 - - $13,342
-
MMBtu
06 2.1213: Direct warmest air to combustion intake $1,342 $500 - - $1,342
-
MMBtu
07 2.4221: Install compressor air intakes in coolest locations $792 $650 $681
8,265
kWh
$111
-
kW-mo/yr
-
08 2.4231: Reduce the pressure of compressed air to the minimum required $576 $25 $494
5,990
kWh
$82
-
kW-mo/yr
-
09 2.4131: Size electric motors for peak operating efficiency $4,196 $10,318 $3,474
42,173
kWh
$722
-
kW-mo/yr
-
10 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $26,053 $13,600 $22,827
277,025
kWh
$3,226
-
kW-mo/yr
-
TOTAL RECOMMENDED $68,682 $42,913 $38,787
456,496
kWh
$5,525
-
kW-mo/yr
$24,370
-
MMBtu
TOTAL IMPLEMENTED $67,340 $42,413 $38,787
456,496
kWh
$5,525
-
kW-mo/yr
$23,028
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs