| Assessment Year | 2013 |
|---|---|
| Principal Product | electric motors |
| NAICS | 335312: Motor and Generator Manufacturing |
| SIC | 3621: Motors and Generators |
| Sales Range | $10 M to 50M |
| # of Employees | 317 |
| Plant Area |
140,000
ft2
|
| Annual Production | 22,000
units
|
| Production Hrs. Annual | 4,810
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $136,431 | 4,470,600 |
kWh
|
$0.031 |
| Electricity Demand | $148,610 | 9,426 |
kW-mo/yr
|
$15.77 |
| Natural Gas | $6,396 | 1,382 |
MMBtu
|
$4.63 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $44,802 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,146 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $23,895 | $202,405 |
$6,050
181,818
kWh
|
$7,045
-
kW-mo/yr
|
- | $10,800 | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $3,231 | $470 |
$1,415
47,018
kWh
|
$1,816
-
kW-mo/yr
|
- | - | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $975 | $2,238 |
$975
32,250
kWh
|
- | - | - | |
| 04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $530 | $105 |
$232
7,696
kWh
|
$298
-
kW-mo/yr
|
- | - | |
| 05 | 2.3212: Optimize plant power factor | $15,108 | $8,304 | - | - | $15,108 | - | |
| 06 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $1,063 | $2,204 |
$1,063
35,401
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $44,802 | $215,726 |
$9,735
304,183
kWh
|
$9,159
-
kW-mo/yr
|
$15,108 | $10,800 | ||
| TOTAL IMPLEMENTED | $17,146 | $12,746 |
$2,038
67,651
kWh
|
- | $15,108 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs