Assessment Year 1994
Principal Product boats
NAICS
n/a
SIC 3732: Boat Building and Repairing
Sales Range $10
M
to 50
M
# of Employees 102
Plant Area 250,000
ft2
Annual Production 6,000
pieces
Production Hrs. Annual 2,000
hrs
Location (State) Mississippi

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $111,965 1,475,381
kWh
Natural Gas $19,992 4,695
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,937 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,441

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $8,462 $18,000 $9,912
84,115
kWh
$(-1,450.0)
-
MMBtu
02 2.3191: Use demand controller or load shedder $5,280 - $5,280
-
kWh
-
03 2.6231: Utilize controls to operate equipment only when needed $4,594 $4,000 $2,760
100,234
kWh
$1,834
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,970 $3,740 $2,970
32,825
kWh
-
05 2.6231: Utilize controls to operate equipment only when needed $2,760 $1,500 - $2,760
-
MMBtu
06 2.2437: Recover waste heat from equipment $1,419 $2,600 - $1,419
-
MMBtu
07 2.2437: Recover waste heat from equipment $1,058 $1,000 - $1,058
-
MMBtu
08 2.7111: Reduce illumination to minimum necessary levels $203 - $203
4,396
kWh
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $191 $161 $191
2,052
kWh
-
TOTAL RECOMMENDED $26,937 $31,001 $21,316
223,622
kWh
$5,621
-
MMBtu
TOTAL IMPLEMENTED $8,441 $3,901 $8,441
34,877
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs