Assessment Year | 2013 |
---|---|
Principal Product | Thermoformed plastic parts |
NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
Sales Range | $5 M to 10M |
# of Employees | 52 |
Plant Area |
100,000
ft2
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 5,430
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $123,078 | 1,343,808 |
kWh
|
$0.092 |
Natural Gas | $5,390 | 696 |
MMBtu
|
$7.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,319 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,643 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,544 | $585 |
$3,544
38,763
kWh
|
|
02 | 2.4322: Use or replace with energy efficient substitutes | $4,344 | $720 |
$4,344
47,590
kWh
|
|
03 | 2.7135: Install occupancy sensors | $755 | $1,617 |
$755
8,271
kWh
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $914 | $490 |
$914
9,996
kWh
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,082 | $105 |
$2,082
22,806
kWh
|
|
06 | 2.4239: Eliminate or reduce compressed air usage | $1,450 | $590 |
$1,450
15,950
kWh
|
|
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $230 | $35 |
$230
2,521
kWh
|
|
TOTAL RECOMMENDED | $13,319 | $4,142 |
$13,319
145,897
kWh
|
||
TOTAL IMPLEMENTED | $8,643 | $2,922 |
$8,643
94,624
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs