| Assessment Year | 2013 |
|---|---|
| Principal Product | Thermoformed plastic parts |
| NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
| SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
| Sales Range | $5 M to 10M |
| # of Employees | 52 |
| Plant Area |
100,000
ft2
|
| Annual Production | 10,000,000
lb
|
| Production Hrs. Annual | 5,430
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $123,078 | 1,343,808 |
kWh
|
$0.092 |
| Natural Gas | $5,390 | 696 |
MMBtu
|
$7.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,319 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,643 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,544 | $585 |
$3,544
38,763
kWh
|
|
| 02 | 2.4322: Use or replace with energy efficient substitutes | $4,344 | $720 |
$4,344
47,590
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $755 | $1,617 |
$755
8,271
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $914 | $490 |
$914
9,996
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,082 | $105 |
$2,082
22,806
kWh
|
|
| 06 | 2.4239: Eliminate or reduce compressed air usage | $1,450 | $590 |
$1,450
15,950
kWh
|
|
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $230 | $35 |
$230
2,521
kWh
|
|
| TOTAL RECOMMENDED | $13,319 | $4,142 |
$13,319
145,897
kWh
|
||
| TOTAL IMPLEMENTED | $8,643 | $2,922 |
$8,643
94,624
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs