Assessment Year | 2012 |
---|---|
Principal Product | Thermoset Composites |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 189 |
Plant Area |
150,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $297,097 | 8,297,592 |
kWh
|
$0.036 |
Electricity Demand | $210,073 | 20,037 |
kW-mo/yr
|
$10.48 |
Electricity Fees | $8,953 | - |
|
- |
Natural Gas | $1,137,674 | 206,290 |
MMBtu
|
$5.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,497 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,219 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,631 | $600 |
$1,706
45,350
kWh
|
$925
-
kW-mo/yr
|
- | |
02 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $2,278 | $530 |
$1,353
35,827
kWh
|
$925
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,619 | $10,841 |
$2,999
79,560
kWh
|
$1,620
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,510 | $18,286 |
$4,226
112,061
kWh
|
$2,284
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $2,096 | $2,626 |
$2,096
55,603
kWh
|
- | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $363 | $175 | - | - |
$363
-
MMBtu
|
|
TOTAL RECOMMENDED | $18,497 | $33,058 |
$12,380
328,401
kWh
|
$5,754
-
kW-mo/yr
|
$363
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,219 | $32,528 |
$11,027
292,574
kWh
|
$4,829
-
kW-mo/yr
|
$363
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs