Assessment Year | 2012 |
---|---|
Principal Product | Automotive Hand tools |
NAICS | 339999: All Other Miscellaneous Manufacturing |
SIC | 3423: Hand and Edge Tools, Except Machine Tools and Handsaws |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
248,500
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $101,967 | 2,876,000 |
kWh
|
$0.035 |
Electricity Demand | $43,490 | 9,312 |
kW-mo/yr
|
$4.67 |
Electricity Fees | $30,761 | - |
|
- |
Natural Gas | $276,767 | 58,142 |
MMBtu
|
$4.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,889 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,985 | $8,240 |
$2,414
55,480
kWh
|
$571
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,402 | $1,618 |
$853
19,600
kWh
|
$549
-
kW-mo/yr
|
|
03 | 2.7135: Install occupancy sensors | $1,963 | $1,193 |
$1,963
45,137
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,615 | $753 |
$1,332
30,552
kWh
|
$283
-
kW-mo/yr
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,152 | $249 |
$1,772
40,740
kWh
|
$380
-
kW-mo/yr
|
|
06 | 2.4239: Eliminate or reduce compressed air usage | $772 | $285 |
$772
17,725
kWh
|
- | |
TOTAL RECOMMENDED | $10,889 | $12,338 |
$9,106
209,234
kWh
|
$1,783
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs