Assessment Year | 2012 |
---|---|
Principal Product | paper packaging |
NAICS | 322121: Paper (except Newsprint) Mills |
SIC | 2621: Paper Mills |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
65,000
ft2
|
Annual Production | 1,000
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,541 | 2,254,700 |
kWh
|
$0.035 |
Electricity Demand | $74,280 | 5,139 |
kW-mo/yr
|
$14.45 |
Electricity Fees | $2,288 | - |
|
- |
Natural Gas | $73,725 | 12,118 |
MMBtu
|
$6.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,020 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $12,154 | $9,240 |
$6,853
194,688
kWh
|
$5,301
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,014 | $238 |
$655
18,572
kWh
|
$359
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,168 | $10,706 |
$4,042
114,816
kWh
|
$3,126
-
kW-mo/yr
|
- | |
04 | 2.4239: Eliminate or reduce compressed air usage | $1,246 | $164 |
$698
19,824
kWh
|
$548
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $1,757 | $5,400 |
$1,757
49,920
kWh
|
- | - | |
06 | 2.2437: Recover waste heat from equipment | $1,452 | $500 | - | - |
$1,452
-
MMBtu
|
|
07 | 2.6218: Turn off equipment when not in use | $1,043 | $25 |
$668
18,980
kWh
|
$375
-
kW-mo/yr
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $3,521 | $540 |
$1,960
55,695
kWh
|
$1,561
-
kW-mo/yr
|
- | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $665 | $50 |
$359
10,216
kWh
|
$306
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $30,020 | $26,863 |
$16,992
482,711
kWh
|
$11,576
-
kW-mo/yr
|
$1,452
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs